10
EN
radiant heater IR 2010 S
Setting the timer
The timer allows you to program an automatic switch-off time in
increments of 1 h up to 24 h at any heating level.
Note
The device should not be left unattended with an
activated timer.
Automatic switch-off
ü
The device is switched on.
1. Press the
Timer
button (
10
) several times to set the
desired number of hours until automatic switch-off.
ð
The segment display (
9
) indicates the set number of
hours until automatic switch-off.
ð
The timer has been programmed and the device will
switch off after the predefined time.
Notes regarding automatic switch-off:
•
Manually switching the device off disables the automatic
switch-off function.
•
If you select 00 hours, the timer will be switched off.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Set the mains switch (
5
) to
0
to switch the device off.
•
Allow the device to cool down completely.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Clean the device according to the Maintenance chapter.
•
Store the device according to the Transport and storage
chapter.
Available accessories
Warning
Only use accessories and additional equipment
specified in the operating manual.
Using insertion tools or accessories other than those
specified in the operating manual may cause a risk of
injury.
Designation
Article number
telescopic tripod
1.410.003.190
Errors and faults
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damage. If you
notice damages, do not try to take the device back into
operation.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
•
Check the on-site fusing.
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device does not emit heat:
•
The heating element may be defective. If the heating
element is defective, have it replaced by a specialist
electrical company.
•
Check the heating level indication in the segment
display (
9
). If
P.0
is displayed, the device is running in
standby mode. Switch the device on by selecting another
heating level between
P.1
and
P.3
.
RCD or another fuse trips:
•
Check the fuse. Switch off any other devices to reduce the
load on the line.
•
Contact a specialist electrical company.
The device slightly vibrates during switch-on and then
stops vibrating:
•
Slight vibrations during switch-on are a normal process.
No measures are required.