oil heater IDS 30 F
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch the device off.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Allow the device to cool down completely.
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Cleaning the housing
Clean the housing with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Wipe the housing dry after cleaning.
Technical annex
Technical data
Parameter
Value
Article number
1.430.000.128
Method of heating
indirect
Air flow rate
1150 m³/h
Fan
axial fan
Max. nominal heat input
34.1 kW
Nominal heat output
28.8 kW (24764 kcal)
Temperature increase ΔT
70 °C
Input voltage
230 V / 50 Hz
Current consumption
1.56 A
Air transport hose connection Ø
300 mm
Flue pipe connection Ø
150 mm
Max. fuel consumption
3.25 l/h
Sound level (at a distance of 1m)
75 dB (A)
Dimensions (length x width x height) 1270 x 470 x 720 mm
Minimum distance to walls and other
objects
A: top
B: rear
C: side
D: front
1 m
1 m
1 m
1 m
Weight
56 kg
Fuels
The following fuels are approved for the device:
•
EL fuel oil
•
Diesel