dehumidifier TTK 125 S
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damage.
•
Check the on-site fusing.
•
Check the filling level of the condensation tank and empty
it if necessary. The
Condensation tank
LED (14) must not
light up.
•
Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
•
Check the float in the condensation tank for dirt. If
necessary, clean the condensation tank. The float must be
able to move freely.
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is running, but there is no formation of
condensate:
•
Check the float in the condensation tank for dirt. If
necessary, clean the condensation tank. The float must be
able to move freely.
•
Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
•
Ensure that the relative room humidity complies with the
technical data.
•
Check the air filter for dirt. If necessary, clean or replace
the air filter.
•
The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.
The device is loud or vibrates:
•
Check whether the device is set up in a stable and upright
position.
Condensate is leaking:
•
Check the device for leaks.
The compressor does not start:
•
Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
•
Check whether the overheating protection of the
compressor has tripped. Disconnect the device from the
mains and let it cool down for approx. 10 minutes before
reconnecting it.
•
The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.
The device gets very warm, is loud or is losing
performance:
•
Check the air inlets and air filters for dirt. Remove external
dirt.
•
From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and air-
conditioning or by Trotec.
Note
Wait for at least 10 minutes after maintenance and
repair work. Only then switch the device back on.
The device still does not operate correctly after these
checks:
Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.
Error codes
The
Status
LED (15) can indicate the following statuses during
operation:
Error message
Meaning
Remedy
Flashing once per
second
Normal operation
No remedy required
Flashing five times
per second
The temperature is
above or below the
limit.
The temperature
should be within the
operating
temperature range
specified in the
Technical data.
The humidity level
has reached the
switching point.
The device will
switch back on once
the humidity level
set is exceeded.
Permanently
illuminated
There is a general
problem.
Please contact the
customer service.
Not illuminated
Summary of Contents for 1120000124
Page 1: ...TRT BA TTK125S TC220617TTRT03 010 EN TTK 125 S EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...
Page 8: ...8 EN dehumidifier TTK 125 S 1 2 3 4 5...
Page 17: ...EN 17 dehumidifier TTK 125 S Wiring diagram With operating hours counter...
Page 18: ...18 EN dehumidifier TTK 125 S With operating hours counter and MID counter...