Operating manual – Axial fan TTV 4500 / TTV 4500 HP / TTV 7000

Transport and storage

Transport

To make the device easier to transport, it is fitted with a
transport loop.
Before transporting the device, proceed as follows:
1. Switch off the device.
2. Pull the plug from the mains socket. Do not use the power

cable to drag the device.

Storage

The devices can also be stacked on top of one another for
storage.
When the device is not being used, observe the following
storage conditions:

Dry.

Protected from dust and direct sunlight.

With a cover to protect it from invasive dust, if necessary.

Set-up and installation

Assembly

Take the device out of the cardboard box and remove the plastic
packaging.

Mounting the foot

1. Attach the foot, the locking screws and the washers as

indicated in the figure below:

Removing the condensate plug

The condensate plug, which is located at the lowest point of the
motor, must be removed before start-up. Store the condensate
plug safely as it must be reinserted for cleaning and
maintenance work.
1. Remove the condensate plug.

Installing the device

Set the device up in a level, upright and stable position.

Do not create tripping hazards when laying the power
cable.

Make sure that the air inlet and outlet are not obstructed.

1. Assemble the device according to the field of application

along with the corresponding accessories. Always use a
tension belt to connect hoses or dust bags.

2. Set the device up in an upright and stable position.
3. Plug the device into a properly fused socket.

ð

The fan is now ready for operation.

Summary of Contents for 1.510.000.010

Page 1: ...TRT BA TTV4500 4500HP 7000 TC 003 EN TTV 4500 TTV 4500 HP TTV 7000 EN OPERATING MANUAL AXIAL FAN ...

Page 2: ... 1 TTV 4500 HP http download trotec com sku 1510000012 id 1 TTV 7000 http download trotec com sku 1510000030 id 1 Legal notice This release replaces all previous versions No part of this pub lication may be reproduced without written permission from Trotec The same applies for electronically processing duplicat ing or spreading the publication Subject to technical changes All rights reserved Trade...

Page 3: ...potentially explosive rooms Do not use the device in aggressive atmosphere Set the device up in an upright and stable position Let the device dry out after a wet clean Do not operate it when wet Ensure that the air inlet and outlet are not obstructed Ensure that the side of the device where the air inlet is found is kept free of dirt and loose objects Observe a minimum distance of 1 5 m between wa...

Page 4: ...angerous toy Behaviour in the event of an emergency 1 In an emergency disconnect the device from the mains feed in Switch the device off and disconnect it from the mains 2 Remove persons from the danger area 3 Do not reconnect a defective device to the mains Information about the device Description of the device The axial fan TTV 4500 TTV 4500 HP TTV 7000 was designed for a high air flow the TTV 4...

Page 5: ...e plastic packaging Mounting the foot 1 Attach the foot the locking screws and the washers as indicated in the figure below Removing the condensate plug The condensate plug which is located at the lowest point of the motor must be removed before start up Store the condensate plug safely as it must be reinserted for cleaning and maintenance work 1 Remove the condensate plug Installing the device Se...

Page 6: ...y for a short time then switches off automatically Check whether the protective grid is blocked and clean it if required The motor bearing or cable connections are defective If so contact Trotec or your dealer The motor or fan is noisy or runs unevenly The fan is soiled Clean the fan according to the Maintenance chapter The fan or the blower unit is damaged If so contact Trotec or your dealer The ...

Page 7: ...es required before starting maintenance Do not touch the mains plug with wet or damp hands Before any work remove the mains plug Danger Maintenance tasks which require the housing or motor to be opened must only be carried out by authorised specialist companies or by Trotec Maintenance activities Regularly check the housing for its perfect condition or for defects Always be mindful of atypical sou...

Page 8: ...45 C 45 C Mains connection 1 N PE 230 V 50 Hz 1 2 A 1 N PE 230 V 50 Hz 1 4 A 1 N PE 230 V 50 Hz 1 9 A Power consumption 0 23 kW 0 35 kW 0 46 kW Fusing 10 A 10 A 10 A Max sound level distance 3 m 53 dB A 64 dB A 58 dB A Mobility portable stackable portable stackable portable stackable Hose connection with hose adapter and or combination distributor 450 mm 8 x 100 mm 450 mm 8 x 100 mm 560 mm Permiss...

Page 9: ...0000634 2 rubber feet back TTV4500 7300001246 3 rubber feet front TTV4500 7300001245 4 housing TTV4500 HP 7310000936 5 safety clamp grid BVVP0023 TTV series 7310000642 6 safety grid airoutlet TTV4500 7242000639 7 safety grid airinlet TTV4500 7242000638 8 fixing knob TTV series 7310000710 9 condensator 6μF motor TTV 7140000357 10 motor 4E40 TTV4500 7110000635 11 connector assembly kit TTV series 73...

Page 10: ...tor 7110000637 04 Bracket 05 Impeller 7310000633 06 Housing set 2pieces 7310000939 Ventilator 7310000938 Motor 07 Frame 7240000939 08 Controller under cap 10 Condense plug 7300001248 on request Disposal In the European Union electronic equipment must not be treated as domestic waste but must be disposed of professionally in accordance with Directive 2002 96 EC of the European Parliament and of the...

Page 11: ... unauthorized changes of the factory supplied device version this declaration loses its legal validity Device version Series Year of manufacture Applicable regulations Applied harmonised standards Producer and authorised representative of the technical documentation Trotec GmbH Co KG Grebbener Straße 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com Heinsberg Managing Director De...

Page 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: