background image

EN

2

Operating manual – Axial fan TTV 4500 / TTV 4500 HP / TTV 7000

Warranty and liability

The device complies with the fundamental health and safety re-
quirements of the applicable EU regulations and was tested at
the factory for perfect functionality multiple times.
However, if faults in the functionality occur and cannot be
remedied with the measures in the chapter Errors and faults,
please get in touch with your dealer or distributor.
When manufacturer's instructions or legal regulations have not
been followed, or after unauthorised changes to the device are
made, the manufacturer is not responsible for the resulting
damages. Changes to the device or unauthorised replacement
of individual parts can drastically impact the electrical safety of
this product and leads to the forfeit of the warranty. Liability
does not extend to damages to people or property caused by the
device being used other than as described in the instructions in
this operating manual. Subject to changes to technical design
and model changes as part of constant development and
product improvement without prior notice.
No liability is accepted for damages resulting from improper
use. In such a case, any warranty claims be voided also.

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!

Danger!
Improper handling can lead to injuries due to parts
being whirled up.

Do not use the device in potentially explosive rooms.

Do not use the device in aggressive atmosphere.

Set the device up in an upright and stable position.

Let the device dry out after a wet clean. Do not operate it
when wet.

Ensure that the air inlet and outlet are not obstructed.

Ensure that the side of the device where the air inlet is
found is kept free of dirt and loose objects.

Observe a minimum distance of 1.5 m between walls,
objects and the suction side.

Never reach or put objects into the device.

Do not cover or transport the device during operation.

Ensure that all electric cables outside of the device are
protected from damage (e.g. from animals). Never use the
device if the cable or power connection is damaged!

Only use extensions to the connecting cable which are
appropriate to the device power consumption, the length of
its cable and its use. Completely unroll extension cables.
Avoid electrical overload.

Pull the plug from the socket if the device is not in use.

Unplug the device from the mains before starting with
maintenance, service or repair work.

Intended use

The axial fan 

TTV 4500 / TTV 4500 HP / TTV 7000

 may be used

for aeration, deaeration, air circulation, dust collection or air
transport whilst adhering to the technical data and the safety in-
structions. The device was designed for the generation of a
powerful, large-volume air circulation, e.g. for the accelerated
drying of buildings and rooms. The fan can be operated in com-
bination with different accessories.

Improper use

The axial fan 

TTV 4500 / TTV 4500 HP / TTV 7000

 is not suited

for installation in fluids or on flooded or boggy grounds. Any un-
authorised changes, modifications or alterations to the device
are forbidden.

Summary of Contents for 1.510.000.010

Page 1: ...TRT BA TTV4500 4500HP 7000 TC 003 EN TTV 4500 TTV 4500 HP TTV 7000 EN OPERATING MANUAL AXIAL FAN ...

Page 2: ... 1 TTV 4500 HP http download trotec com sku 1510000012 id 1 TTV 7000 http download trotec com sku 1510000030 id 1 Legal notice This release replaces all previous versions No part of this pub lication may be reproduced without written permission from Trotec The same applies for electronically processing duplicat ing or spreading the publication Subject to technical changes All rights reserved Trade...

Page 3: ...potentially explosive rooms Do not use the device in aggressive atmosphere Set the device up in an upright and stable position Let the device dry out after a wet clean Do not operate it when wet Ensure that the air inlet and outlet are not obstructed Ensure that the side of the device where the air inlet is found is kept free of dirt and loose objects Observe a minimum distance of 1 5 m between wa...

Page 4: ...angerous toy Behaviour in the event of an emergency 1 In an emergency disconnect the device from the mains feed in Switch the device off and disconnect it from the mains 2 Remove persons from the danger area 3 Do not reconnect a defective device to the mains Information about the device Description of the device The axial fan TTV 4500 TTV 4500 HP TTV 7000 was designed for a high air flow the TTV 4...

Page 5: ...e plastic packaging Mounting the foot 1 Attach the foot the locking screws and the washers as indicated in the figure below Removing the condensate plug The condensate plug which is located at the lowest point of the motor must be removed before start up Store the condensate plug safely as it must be reinserted for cleaning and maintenance work 1 Remove the condensate plug Installing the device Se...

Page 6: ...y for a short time then switches off automatically Check whether the protective grid is blocked and clean it if required The motor bearing or cable connections are defective If so contact Trotec or your dealer The motor or fan is noisy or runs unevenly The fan is soiled Clean the fan according to the Maintenance chapter The fan or the blower unit is damaged If so contact Trotec or your dealer The ...

Page 7: ...es required before starting maintenance Do not touch the mains plug with wet or damp hands Before any work remove the mains plug Danger Maintenance tasks which require the housing or motor to be opened must only be carried out by authorised specialist companies or by Trotec Maintenance activities Regularly check the housing for its perfect condition or for defects Always be mindful of atypical sou...

Page 8: ...45 C 45 C Mains connection 1 N PE 230 V 50 Hz 1 2 A 1 N PE 230 V 50 Hz 1 4 A 1 N PE 230 V 50 Hz 1 9 A Power consumption 0 23 kW 0 35 kW 0 46 kW Fusing 10 A 10 A 10 A Max sound level distance 3 m 53 dB A 64 dB A 58 dB A Mobility portable stackable portable stackable portable stackable Hose connection with hose adapter and or combination distributor 450 mm 8 x 100 mm 450 mm 8 x 100 mm 560 mm Permiss...

Page 9: ...0000634 2 rubber feet back TTV4500 7300001246 3 rubber feet front TTV4500 7300001245 4 housing TTV4500 HP 7310000936 5 safety clamp grid BVVP0023 TTV series 7310000642 6 safety grid airoutlet TTV4500 7242000639 7 safety grid airinlet TTV4500 7242000638 8 fixing knob TTV series 7310000710 9 condensator 6μF motor TTV 7140000357 10 motor 4E40 TTV4500 7110000635 11 connector assembly kit TTV series 73...

Page 10: ...tor 7110000637 04 Bracket 05 Impeller 7310000633 06 Housing set 2pieces 7310000939 Ventilator 7310000938 Motor 07 Frame 7240000939 08 Controller under cap 10 Condense plug 7300001248 on request Disposal In the European Union electronic equipment must not be treated as domestic waste but must be disposed of professionally in accordance with Directive 2002 96 EC of the European Parliament and of the...

Page 11: ... unauthorized changes of the factory supplied device version this declaration loses its legal validity Device version Series Year of manufacture Applicable regulations Applied harmonised standards Producer and authorised representative of the technical documentation Trotec GmbH Co KG Grebbener Straße 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com Heinsberg Managing Director De...

Page 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...