Installation Guide Qiwi Switches
Document no. 120-10X.44 11/2016 ENG
Seite 8 von 16
3.2.
Assignment of the terminal block
DANGER!
Never perform wiring electrical connections if they are under voltage!
Order no. 006-120-100
Pin
Assignment Connection
Image
1
V1
Power supply 1 plus pole
2
GND
Power supply 1 minus pole
3-6
N/A
not connected
7
GND
Power supply 2 minus pole
8
V2
Power supply 2 plus pole
Order no. 006-120-101
Pin
Assignment Connection
Image
1
V1
Power supply 1 plus pole
2
GND
Power supply 1 minus pole
3
FAULT
Fault contact
4
DI+
Digital input plus pole
5
DI-
Digital input minus pole
6
FAULT
Fault contact
7
GND
Power supply 2 minus pole
8
V2
Power supply 2 plus pole
3.3.
Connection of USB port
Order no. 006-120-101
The connection is performed vie USB-A-Type connection of the device.
Pin
Assignment Connection
Illustration
1
VBUS
+5V
2
D-
Data -
3
D+
Data +
4
GND
Mass (not connected to shielding)
3.4.
Connection of Ethernet ports
The connection is performed via the RJ-45 connectors (8P8C-jacks) of the device.
Pin
Assigment
Connection
Illustration
1
TX+
Data TX+
2
TX-
Data TX-
3
RX+
Data RX+
4
not connected
5
not connected
6
RX-
Data RX-
7
not connected
8
not connected