CALIBRATION OF INSTRUMENTATION
(
continued
)
12.3
ANALOG PRESSURE GAUGE (Hand Pump Pressure-
Option M Only
)
12.3.1
Self Calibration
An accurate pressure calibration gauge is required for calibration of the Hand Pump Pressure gauge. Follow the necessary
steps below.
Shut off the HPU and disconnect it from the power source. Remove the
Hydraulic Panel
from the front instrument panel (four
screws). Disconnect the hose from the Hand Pump Pressure gauge (remove gauge from panel if necessary). Attach
calibration test equipment to the gauge and record gauge values at the designated increments.
12.4
ANALOG TEMPERATURE GAUGE
(Pyrometer)
12.4.1
Self Calibration
An accurate temperature calibration gauge is required for calibration of the Pyrometer. The pyrometer bulb is located in the
return manifold (rear of unit) and can be accessed by removal of the HPU top panel. See Section
9.7.2
Pyrometer
for
location. Follow the necessary steps below.
1. Remove the pyrometer bulb from the return manifold by removing the slotted brass nut that retains the bulb in the well.
2. Connect the temperature calibration gauge to the bulb of the pyrometer.
The Temperature Value Must Be:
Pyrometer Temperature Display
(
F)
Minimum Acceptable
(
F)
Maximum Acceptable
(
F)
Temperature
Calibration gauge
(
F)
160
158
162
HAND PUMP PRESSURE GAUGE (HC-2146)
Applied Pressure
(Hand Pump
Pressure Gauge)
(psig)
Minimum
Acceptable
(psig)
Maximum
Acceptable
(psig)
Gauge Movement
(Direction)
Indicated Pressure
(Calibration Gauge)
(psig)
1000
700
1300
Increasing
2000
1700
2300
Increasing
5000
4800
5200
Increasing
8000
7700
8300
Increasing
10,000
9700
10,300
Increasing
8000
5940
8300
Decreasing
5000
4800
5200
Decreasing
2000
1700
2300
Decreasing
1000
700
1300
Decreasing
Allowable operating tolerance:
+/- 3% of full scale (300 psig) at room temperature (70
F).
+/- 2% of full scale for middle third of scale (200 psig) at room temperature (70
F).
Summary of Contents for 5731
Page 55: ...Model 5731 Hydraulic Power Unit 08 2016 Rev 08 Page 50 This page left blank intentionally...
Page 66: ......
Page 67: ...APPENDIX I Declaration Of Conformity...
Page 68: ......
Page 70: ......
Page 71: ...APPENDIX II Hydraulic Schematic INS 1660...
Page 72: ......
Page 73: ...APPENDIX III Electrical Schematic INS 1608 INS 2016...
Page 74: ......
Page 75: ...APPENDIX IV Wiring Diagram INS 1597 INS 2046...
Page 76: ......
Page 77: ...APPENDIX IV Lincoln Motor Manual...
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ...APPENDIX V Oilgear Pump Manual...
Page 84: ......
Page 85: ......
Page 86: ......
Page 87: ......
Page 88: ......
Page 89: ......
Page 90: ......
Page 91: ......
Page 92: ......
Page 93: ......
Page 94: ......
Page 95: ......
Page 96: ......
Page 97: ......
Page 98: ......
Page 99: ......
Page 100: ......
Page 101: ...APPENDIX VI Material Safety Data Sheet MSDS Hydraulic Fluid...
Page 102: ......
Page 103: ......
Page 104: ......
Page 105: ......
Page 106: ......
Page 107: ......
Page 108: ......
Page 109: ......
Page 110: ......
Page 111: ...APPENDIX VII ANSI B93 19M 1972 R1993 Excerpt...
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ......
Page 116: ......
Page 117: ...APPENDIX VIII Instrument Certification Notice...
Page 118: ......