During the exposure time, the status indicator light
glows blue. After this, the cooling phase is set for
10 seconds (yellow flashing light).
When switched off, the device remains in factory
mode.
6.1.2 Impressions up to 20 x 20 mm
1. In order to activate the 0,5 second mode, keep
the push button pressed when you are switching
the exposure unit on.
2. Place the exposure unit flush over the fresh
impression.
3. Briefly press the push button.
A fully covered impression cures after a 0.5 second
exposure time.
The device remains in 0,5 second mode after swit-
ching off and on again. To switch to the 2-second
factory mode, press and hold the push button while
switching on.
6.3 Limits of use
• The light sources (LEDs) cannot be replaced.
• In case of defective light sources, replace the
entire dryteq UV exposure device.
• The permissible operating temperature
is 0°C to 45°C.
EN
15
Summary of Contents for DRYTEQ SET
Page 92: ...REF_164996_M06C3A20 ...