TL-3120 Motion Control User Manual
WWW.SZTROCEN.COM
30
check whether the motion direction is the same as key direction. If not,
please modify the
【
Key Direction
】
on the axis parameters page.
3.5 Distance Per Pulse
Distance per pulse refers to the actual distance of motion axis for each
pulse instruction sent by the controller. The calculation method is as
follows (take the X-axis as an example).
1)
Open the
【
XY AutoReset
】
function, and reset machine, then mark the
current position of laser head with A.
2)
On the main page, press
【
Menu
】
and enter the
Jog Control
page. Set
the
【
Jog Distance
】
to 200mm as example. Then press
【
Enter
】
to save
your modification. If you did not set the
【
Range
】
on
Axis Parameters
page, please do not set the
【
Jog Distance
】
value too large.
3)
On the
Jog Control
page, move cursor to
【
X/Y Jog
】
, then press
direction key (
【←】
/
【→】
) one time to make the laser head move
a jog distance on the X direction. Mark the current position of laser
head with B.
4)
Measure the distance between A and B, then input the value into
【
Actual Length
】
.
5)
On the main page, press
【
Stop
】
+
【
Shift
】
at the same time to open
the
Manufacture Params Settings
page. Then move cursor to
【
Axis
Parameters
】
option and press
【
Enter
】
. Then open the
X Axis
Parameters
page and move cursor to
【
Distance Per Pulse
】
, press