Programming table of the most important CVs
CV Designation
Meaning
Area
Factory setting
1
Locomotive address
DCC address of the locomotive
1 – 119
3
2
Starting voltage
Changes the minimum speed
0 – 63
4
3
Acceleration time
Value * 0.87 gives the time
0 – 63
8
from shutdown to top speed
4
Braking time
Value * 0.87 gives the time
0 – 63
6
from top speed to shutdown
5
Top speed
Speed of the locomotive
0 – 63
63
at the top speed level
6
Middle speed
Speed of the locomotive at the middle speed level.
0 – 63
25
CV 6 must be less than CV 5
8
Basic setting
8 = Restore basic
8
–
factory settings
17+18
Expanded
Long address. CV 17 = higher-value bit,
128 – 9999
0
locomotive address
CV 18 = lower-value bit.
Long address must be activated
in CV 29 / bit 5.
29
Configuration register
Caution! Very complex!
0, 1, 2, 3, 4,
4
Total value must be calculated.
5, 6, 7, 16, 17,
Total value = value of bit0 + value of bit1
18, 19, 20, 21,
+ value of bit2 + value of bit4 + value of bit5
22, 23, 32, 33,
34, 35, 36, 37,
38, 39, 48, 49,
50, 51, 52, 53,
54, 55
Bit Function
Val.
0
Normal direction of travel
0
Inverse behaviour
1
1
14 speed levels
0
28 or 128 speed levels
2
Summary of Contents for 22599
Page 1: ...22599...