CHAPTER 5 COPIER DEFAULT SETTING
5-3
Default code
F12
F13
F14
F15
F16
Setting item
Silent mode
Auto shut-off
Auto preheat time
Auto shut-off time
Preheat recovery time
Setting code
1: 0 seconds
2: 5 seconds
3: 10 seconds*
4: 15 seconds
5: 30 seconds
1: ON*
2: OFF
1: 5 minutes
2: 10 minutes
3: 15 minutes*
4: 20 minutes
5: 25 minutes
6: 30 minutes
7: 35 minutes
8: 40 minutes
9: 45 minutes
1: 15 minutes
2: 30 minutes*
3: 45 minutes
4: 60 minutes
5: 75 minutes
6: 90 minutes
7: 105 minutes
8: 120 minutes
1: Recovery priority mode
2: Power save priority
mode*
Setting contents
Selects the length of time from when copying ends to
when entering the silent mode, which stops the motors
inside the copier. When “0 seconds” is selected, the
motors stop immediately after copying has been
finished.
Turns the auto shut-off function (page 4-4) ON or OFF.
The auto shut-off function automatically turns the main
switch OFF if copying is not performed for a certain
period of time.
* If auto shut-off interferes with your copying operations,
turn this function OFF. It is recommended to set a
longer interval for triggering the auto shut-off rather
than turn it OFF.
Selects the length of time from when copying ends to
when the energy saver (auto preheat) function (page
4-4) is triggered.
Selects the length of time from when the copier is not
used to when the auto shut-off function (page 4-4) turns
the main switch OFF automatically. The auto shut-off
function can also be turned OFF. If turned OFF, this
setting cannot be made (see “Auto shut-off”).
* This setting item will not be displayed if “OFF” is
selected for “Auto shut-off”.
* It is recommended to set a long period of time to
trigger the auto shut-off if the copier is used frequently,
and set a short period of time if the copier is used only
occasionally.
* For how to cancel the auto shut-off function, see “Auto
shut-off”.
Selects the mode of the energy saver (auto preheat)
function (page 4-4) from the recovery priority mode and
power save priority mode. The length of time that the
copier uses to recover from the energy saver (auto
preheat) function can be selected between within 10
seconds (recovery priority mode) and within 30 seconds
(power save priority mode).