Main menu 0

 

 

 

Press [MODE/ESC] to enter the main menu "MODE" (display flashing) 
Press [ENTER] and select "ADDR", “RUN” or "DISP" by pressing [UP] or [DOWN] button. 
Press [ENTER] for selecting the desired sub menu. 
 

DMX address setting, Slave setting

 

 

 

 

DMX address setting

 

With this function, you can adjust the desired DMX-address via the Control Board. 
Select “VALU” by pressing [UP] or [DOWN] button. 
Press [ENTER], adjust the DMX address by pressing [UP] or [DOWN] button. 
Press [ENTER] to confirm or pressing [MODE/ESC] to return to main menu. 
 

Slave setting

 

With this function, you can define the device as slave. 
Select “SLAV” by pressing [UP] or [DOWN] button. 
Press [ENTER], the display shows “ON” or “OFF”. 
Press [UP] to select “ON” if you wish to enable this function or press [DOWN] to select “OFF” if you don’t.       
Press [ENTER] to confirm or press [MODE/ESC] to return to main menu. 
 

-

DMX address setting via controller

 

With this function, you can adjust the desired DMX-address via an external controller. 
This function can only be activated when the DMX-value of all other channels is set to "0" on the 
controller. 
Select “EBOC” by pressing [UP] or [DOWN]. 
Press [ENTER], the display shows “ON” or “OFF”. 
Press [UP] to select “ON” if you wish to enable this function or [DOWN] to select “OFF” if you don’t. 
Press [MODE/ESC] to confirm. 
Press [ENTER] in order to return to the main menu. 
On the controller, set the DMX-value of channel 1 to "7". 
Set the DMX-value of channel 2 to "7"or "8". When set to "7" you can adjust the starting address between 1 
and 255. When set to "8" you can adjust the starting address between 256 and 511. 
Set the DMX-value of channel 3 to the desired starting address. If you want to set the starting address to 57, set 
channel 1 to "7", channel 2 to "7" and channel 3 to "57". If you want to set the starting address to 420, set 
channel 1 to "7", channel 2 to "8" and channel 3 to "164" (256+164=420). 
Wait for approx. 20 seconds and the unit will carry out a reset. After that, the new starting address is set. 
     

Program Run, Master setting

 

With the function "RUN", you can run the internal program. You can set the number of steps under Step. You 
can edit the individual scenes under Edit. You can run the individual scenes either automatically (AUTO), i.e. 
with the adjusted Step-Time or sound-controlled (SOUN). The selection "ALON" means Stand Alone-mode 

Summary of Contents for WALLY SC 20

Page 1: ...PROFESSIONAL SCANNER USER MANUAL WALLY SC 20 KEEP THIS MANUAL FOR FUTURE NEEDS...

Page 2: ......

Page 3: ...pack the device Inside the box you should find 1 One XLR connection cable 2 One power cable 3 One safety rope 4 Manual Features LED type SST 50 Extremely Long Life 100 000 hr and lower power consumpti...

Page 4: ...subject to warranty The dealer will not accept liability for any resulting defects or problems If the device has been exposed to temperature changes due to environmental changes do not switch it on i...

Page 5: ...lified person in order to avoid a hazard Please be aware that damages caused by manual modifications to the device are not subject to warranty Keep away from children and non professionals GENERAL GUI...

Page 6: ...n of the effect has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation The installation must always be secured with a secondary safety...

Page 7: ...XLR input of the moving head You can chain multiple Moving head together through serial linking The cable needed should be two core screened cable with XLR input and output connectors Please refer to...

Page 8: ...e In the case of the scanner which is 9 channel fixture you should set the starting address of the first unit to 1 the second unit to 10 9 1 the third to 19 10 9 and so on Note The modes of DMX 512 da...

Page 9: ...nge DMX address via external controller ALON AU A Automatic Run in Stand Alone AUTO MAST AU M Automatic Run as Master ALON SO A Sound controlled Run in Stand Alone RUN SOUN MAST SO M Sound controlled...

Page 10: ...s is set to 0 on the controller Select EBOC by pressing UP or DOWN Press ENTER the display shows ON or OFF Press UP to select ON if you wish to enable this function or DOWN to select OFF if you don t...

Page 11: ...of the selected channel Reverse display With this function you can rotate the display by 180 Select RDIS by pressing UP or DOWN button Press ENTER the display shows ON or OFF Press UP to select ON if...

Page 12: ...you can adjust the sensitivity of the microphone 1 Select MIC by pressing UP or DOWN button Press ENTER the display shows M XX XX stands for the number from 0 to 99 3 Press ENTER to confirm or Press...

Page 13: ...version With this function you can display the software version of the device Select VER by pressing UP or DOWN button Press ENTER the display shows V X X X X stands for the version number e g V 1 0 V...

Page 14: ...t MATI by pressing UP or DOWN button Press ENTER the display shows XXXX X stands for the number of hours Press ENTER to confirm or Press MODE ESC to return to the main menu Lamp running time With this...

Page 15: ...hange the scene no by pressing UP or DOWN button Press ENTER the display shows C X X stands for the channel no Such as C 01 it means you are editing channel 1 of the selected scene Select the channel...

Page 16: ...The number of steps can be defined under STEP and the scenes can be called up under RUN INSTRUCTIONS ON USE DMX channel s functions and their values 9 DMX channels Channel Value Function Color Wheel...

Page 17: ...ovement 8bit 6 0 255 Tilt Movement Shutter strobe 0 31 Shutter closed 32 63 No function shutter open 64 95 Strobe effect slow to fast 96 127 No function shutter open 128 159 Pulse effect in sequences...

Page 18: ...GOBOS ROTATION yoke movement error This message will appear after the reset of the fixture if the yoke s magnetic indexing circuit malfunction sensor failed or magnet missing or the stepping motor is...

Page 19: ...AC 208V 50Hz AC 220V 50Hz AC 230V 50Hz AC 240 V 50Hz AC 100V 60Hz AC 120V 60Hz AC 208V 60Hz AC 220V 60Hz AC 230V 60Hz AC 240 V 60Hz Power consumption max 80W Packing dimensions 67 5 x 37 x 33cm Net we...