![Tritech Dual Frequency Echosounder Product Manual Download Page 13](http://html1.mh-extra.com/html/tritech/dual-frequency-echosounder/dual-frequency-echosounder_product-manual_1168957013.webp)
Specification
Altimeter Product Manual
0286-SOM-00001, Issue: 09
13
© Tritech International Ltd.
1.5. LRPA Electrical & Acoustic
Acoustic
Operating frequency
200kHz
Beamwidth
10° conical
Range
2 to 200m
Digital timing resolution
1mm
Analogue resolution
0.025% of range
Electrical and Communication
Power supply
24V DC at 90mA (12V DC optional)
Analogue output
0 to 10V DC (with 24V power supply)
0 to 5V DC
4 to 20mA
Communication protocols
RS232 or RS485
Output modes
Free running, interrogated
or part of multidrop network
1.6. LRPA Physical & Environmental
Physical
Standard model
Deep rated model
Weight in air
1.3kg
4.33kg
Weight in water
0.95kg
2.93kg
Depth rating
4000m
6000m
Materials
Aluminium alloy housing
Stainless Steel housing
Stainless Steel housing
Operating temperature
-10 to 35°C
Storage temperature