Page 1: ...00 value www tripplite com warranty 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2018 Tripp Lite All rights reserved Este manual esta disponible en espa ol en la p gina...

Page 2: ...dentifier Compatible with HDMI versions 1 0 through 2 1 Fast and accurate verification of HDMI cables with Type A A A C or C C connectors Displays 19 pin to pin wire map and shield connection status t...

Page 3: ...e one at a time When testing uninstalled patch cable you can leave the Main Tester and Remote Identifier connected When testing installed cable you will need to remove the Remote Identifier from the M...

Page 4: ...with diagrams showing which pins should illuminate for each connection type Note When no connection is detected between the connectors of the cable being tested the LEDs will not illuminate Straight...

Page 5: ...ate to show in what order they are wired For example in the diagram below when the Master unit shows pin 14 illuminated pin 19 on the Remote unit will illuminate indicating those connections are cross...

Page 6: ...onnections Open Circuit If the same LEDs on both the Master and Remote units remain off the corresponding wire is an open circuit Master Remote Power Off Continuity Sweep 04 380 933794 EN indd 6 5 7 2...

Page 7: ...Short Circuit If a short circuit is detected the Remote unit s LEDs will not illuminate but the Master units LEDs will illuminate brighter Master Remote Power Off Continuity Sweep 04 380 933794 EN in...

Page 8: ...ules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause...