background image

35

WARNING

Use of this equipment in life support applications where failure of this equipment can reasonably 

be expected to cause the failure of the life support equipment or to significantly affect its safety 
or effectiveness is not recommended. Do not use this equipment in the presence of a flammable 

anesthetic mixture with air, oxygen or nitrous oxide.

FCC Notice, Class B

This device complies with part 15 of the FCC Rules. Operation is subject to the following two 

conditions: (1) This device may not cause harmful interference, and (2) this device must accept 
any interference received, including interference that may cause undesired operation.

Note: 

This equipment has been tested and found to comply with the limits for a Class B digital 

device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, 

uses and can radiate radio frequency energy and, if not installed and used in accordance with 

the instructions, may cause harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of 

the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.

• Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications to this equipment not expressly approved by Tripp Lite could void the 
user’s authority to operate this equipment.

WEEE Compliance Information for Tripp Lite Customers and Recyclers (European Union)

Under the Waste Electrical and Electronic Equipment (WEEE) Directive and implementing 

regulations, when customers buy new electrical and electronic equipment from Tripp Lite 

they are entitled to:
• Send old equipment for recycling on a one-for-one, like-for-like basis  

(this varies depending on the country)

• Send the new equipment back for recycling when this ultimately becomes waste

Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.

Additional Warnings and Notices 

15-08-104-933289-EN.indd   35

8/21/2015   3:45:52 PM

Summary of Contents for B130-101-2

Page 1: ...epeater Models B132 100 1 B132 100A B132 100 WP 1 B132 100A WP 1 B132 110 and B132 110A 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2015 Tripp Lite All rights reserved...

Page 2: ...00A WP 1 9 B132 110 9 B132 110A 10 Optional Accessories 10 Mounting Hardware 11 Instructions Installation 12 EDID Copy 12 Extender Kit Installation 14 Non Kit Standard Installation 17 Non Kit Daisy Ch...

Page 3: ...L L L L R R R R R R 1 or 2 External Power Supplies Input 100 240V 50 60Hz 0 5A Output 5V 2A 2 2 2 2 2 2 2 0 1 1 1 1 1 1 1 1 1 1 1 Mounting Hardware X X X X X X X X X X X X X X Wallplate Screws X X X...

Page 4: ...4 x 768 60Hz and an audio signal up to 1 000 ft from the source Features additional VGA and 3 5mm ports allowing for the connection of a local monitor and speakers Includes mounting hardware that allo...

Page 5: ...cal transmitter and remote repeater units Locate multiple monitors at different points in a chain of up to 2 000 ft by connecting an additional remote receiver unit B132 100 1 or B132 100 WP 1 or a re...

Page 6: ...onal 1 000 ft from the first remote repeater unit to the last set of display and speakers in the installation for a maximum extension distance of 2 000 ft Local unit includes additional VGA video and...

Page 7: ...wall mounted rack mounted or pole mounted EDID copy feature ensures optimal display compatibility B132 004 2 Features an additional VGA port allowing for the connection of a local monitor Works with...

Page 8: ...be connected to a Tripp Lite B132 004 RB rackmount bracket and mounted in just 1U of rack space EDID copy feature ensures optimal display compatibility B132 008A 2 Works with the B132 100A and B132 10...

Page 9: ...ed Features built in equalization and gain controls to adjust the video image B132 110 Extends and expands your Tripp Lite VGA over Cat5 installation allowing you to locate multiple monitors at differ...

Page 10: ...allowing you to locate multiple monitors speakers at different points in a chain of up to 2 000 ft Up to 4 remote units 3 remote repeaters and 1 receiver can be connected together providing audio vide...

Page 11: ...how a B140 101X DVI Extender but mounting is the same for the VGA Extenders The B132 004 2 and B132 004A 2 can also be mounted to a Tripp Lite B132 004 RB 1U rackmount bracket Up to 3 B132 004 2 or B1...

Page 12: ...o supported by monitors B and C Monitor A is also a good choice because all of its supported resolutions are also supported by monitors B and C A 1920 x 1080 1600 x 1200 1024 x 768 B 1920 x 1080 1680...

Page 13: ...isconnect the monitor from the transmitter unit s input port and proceed per the installation instructions in this manual 5 You can verify that the EDID information was copied via the Display Settings...

Page 14: ...To achieve maximum distance and performance 24 AWG solid wire Cat5e 6 cable must be used The use of stranded wire Cat5e 6 cable or cable with a gauge AWG size higher than 24 AWG will result in shorter...

Page 15: ...nnecting a local monitor and speakers the source can be connected directly to the INPUT port s on the transmitter unit without using the included splitter cable 6 Optional Connect a local monitor and...

Page 16: ...power from the USB cable built in to the transmitter unit and doesn t require external power supplies 13 Turn on the power to the monitor speakers and RS 232 serial device 14 Turn on the power to the...

Page 17: ...s walls 4 To achieve maximum distance and performance 24 AWG solid wire Cat5e 6 cable must be used The use of stranded wire Cat5e 6 cable or cable with a gauge AWG size higher than 24 AWG will result...

Page 18: ...6 Repeat step 5 for each receiver unit you are connecting to the installation 7 Connect a monitor and speakers to the OUTPUT port s on the receiver unit using a VGA and audio cable 8 Repeat step 7 for...

Page 19: ...ough ceilings walls 4 To achieve maximum distance and performance 24 AWG solid wire Cat5e 6 cable must be used The use of stranded wire Cat5e 6 cable or cable with a gauge AWG size higher than 24 AWG...

Page 20: ...ribution Unit PDU or Uninterruptible Power Supply UPS 7 Repeat step 6 for each additional transmitter unit in the installation 8 Using Cat5e 6 cable connect an available RJ45 OUTPUT port on the transm...

Page 21: ...ote units connected Installation will be the same for the B130 111 except there will be no audio connections Installation will be the same for the B130 101 2 and B130 101A 2 except that instead of add...

Page 22: ...port s on the transmitter unit using a VGA video and audio cable 4 Connect the external power supply to the transmitter unit and then plug it into a Tripp Lite Surge Protector Power Distribution Unit...

Page 23: ...ps 8 through 10 11 Using Cat5e 6 cable connect the RJ45 OUTPUT port on the last remote repeater unit to the RJ45 INPUT port on a receiver unit Note If you have a B130 101 2 or B130 101A 2 extender kit...

Page 24: ...with 2 ports instead of 4 and do not feature additional ports for a local monitor and speakers 3 A 1024 x 768 60Hz signal can be extended up to 1 000 ft between the local transmitter and the first rem...

Page 25: ...monitor and speakers to the LOCAL port s on the transmitter unit using a VGA video and audio cable 4 Connect the external power supply to the transmitter unit and then plug it into a Tripp Lite Surge...

Page 26: ...g Cat5e 6 cable connect the RJ45 OUTPUT port on the last remote repeater unit to the RJ45 INPUT port on a receiver unit 12 Connect a monitor and speakers to the OUTPUT port s on the receiver unit usin...

Page 27: ...llation B132 004 2 B132 004A 2 and B132 008A 2 only Installation continued Note 1 For models that support EDID copy perform the EDID copy procedure described in this manual prior to installation 15 08...

Page 28: ...6 cable must be used The use of stranded wire Cat5e 6 cable or cable with a gauge AWG size higher than 24 AWG will result in shorter extension distance All Tripp Lite N202 Series cables are made with...

Page 29: ...dio cable 8 Connect the external power supply to the remote repeater unit and then plug it into a Tripp Lite Surge Protector Power Distribution Unit PDU or Uninterruptible Power Supply UPS The Red pow...

Page 30: ...unit and then plug it into a Tripp Lite Surge Protector Power Distribution Unit PDU or Uninterruptible Power Supply UPS Repeat steps 6 through 14 for each additional RJ45 OUTPUT port on each of the t...

Page 31: ...tween the source and the display Tripp Lite s VGA over Cat5 extender kits and transmitters that have a 2 at the end of their model name include an EDID copy feature which stores a monitor s EDID infor...

Page 32: ...ft for the B130 101 U use Zero Skew cable such as Tripp Lite P524 01K Also the VGA cables you are using must support the resolution you are trying to obtain Inexpensive low quality VGA cables may not...

Page 33: ...r cabling for any damages that may have occurred during installation If a cable connector is loosened from pulling through ceilings walls or the cable jacket is damaged causing the wiring to be expose...

Page 34: ...y EXCEPT AS PROVIDED HEREIN TRIPP LITE MAKES NO WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some states do not permit limitation or exclu...

Page 35: ...l not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is enco...

Page 36: ...36 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 15 08 104 93 3289_revC 15 08 104 933289 EN indd 36 8 21 2015 3 45 52 PM...