Carbon Monoxide Meter 

Introduction 

 

Thank  you  for  selecting the  Triplett  GSM130  Carbon  Monoxide  Meter. 

The GSM130 is a digital, pen style meter, that measures and displays 

carbon  monoxide  (CO)  concentrations  between  0  and  999  parts  per 

million (ppm). The GSM130 can be used for ambient air safety checks of 

residential areas, appliances, HVAC service on furnaces and hot water 

heaters,  home  inspections,  and  industrial  environments  where  the 

accumulation of CO is possible. 

5 Commonwealth Ave

5 Commonwealth Ave

  

Woburn, MA 01801

Woburn, MA 01801

  

Phone 781-665-1400

Phone 781-665-1400  

Toll

Toll

  

Free 1-800-517-8431

Free 1-800-517-8431

Visit

 us at www.TestEquipmentDepot.com

Summary of Contents for GSM130

Page 1: ...9 parts per million ppm The GSM130 can be used for ambient air safety checks of residential areas appliances HVAC service on furnaces and hot water heaters home inspections and industrial environments where the accumulation of CO is possible 5 Commonwealth Ave 5 Commonwealth Ave Woburn MA 01801 Woburn MA 01801 Phone 781 665 1400 Phone 781 665 1400 Toll Toll Free 1 800 517 8431 Free 1 800 517 8431 ...

Page 2: ...e Monitor has not been tested by an independent lab to comply with UL 2034 or IAS 6 96 standard It is the responsibility of the customer to obtain and apply current local state and national regulations with regard to CO alarms monitoring and testing Electromagnetic EMI interference my cause erratic meter readings do not place meter near areas of high EMI when taking CO measurements Recovery time i...

Page 3: ...riod according to OSHA 200 PPM Mild headache fatigue nausea and dizziness after 2 3 hours 400 PPM Frontal headache with 1 2 hours life threatening after 3 hours 800 PPM Dizziness nausea convulsions within 45 minutes Unconsciousness within 2 hours DEATH WITHIN 2 TO 3 HOURS 1600 PPM Headache dizziness nausea within 20 minutes DEATH WITHIN 1 HOUR 3200 PPM Headache dizziness nausea within 5 10 minutes...

Page 4: ...y Display 4 Unit of measure Button Descriptions Turn the meter on and off short press Select alarm setpoint value long press from a powered OFF state release the button when desired alarm limit is displayed Turn the backlight on and off short press Toggle temperature units long press during self test period Reset Maximum CO value long press in normal operating mode ...

Page 5: ...er beeps and enters the normal operating mode Measurements The CO15 detects the existence of carbon monoxide CO in the environment and displays the reading in parts per million PPM in the primary display 1 To take a measurement trace the CO15 around the area of the suspected leak 2 The meter indicates the presence of carbon monoxide CO in PPM in the primary display The secondary display indicates ...

Page 6: ...O levels Change the alarm limit value by following the steps below 1 Turn OFF the meter by pressing the button 2 Long press the button until the options display on the screen 3 The LCD cycles through these options 25 30 35 45 50 70 100 200 ppm 4 Release the button at the desired alarm limit value 5 The meter enters the self test mode Backlight The meter features a backlit LCD for use in dimly lit ...

Page 7: ... the battery and store separately Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take end of life devices...

Page 8: ... 47 x 28mm 6 9 x 1 8 x 1 1 158 8g 5 6 oz Troubleshooting Error Problem Solution Ensure batteries are Display No display when pressing properly installed with power button correct polarity Replace batteries Check for low battery Display Display switches off indicator replace batteries Check for low battery Display Calibration Failure indicator replace batteries E2 Measurement is below Check reading...

Page 9: ...ply to any of our products which have been repaired or altered by unauthorized persons in any way or purchased from unauthorized distributors so as in our sole judgment to injure their stability or reliability or which have been subject to misuse abuse misapplication negligence accident or which have had the serial numbers altered defaced or removed Accessories including batteries are not covered ...