User’s Manual

Water Product 

TM

NWL

NWL-TRN-001

Summary of Contents for NWL

Page 1: ...User s Manual Water Product TM NWL NWL TRN 001 ...

Page 2: ... damages by shutting down the water supply when there is no activity and or a flooding is indicated within the system Each system is comprised of a Shut Off unit valve installed on the main water supply pipe a flood detector and a control unit for closing and opening the valve The system presents the user with a clear and simple indication of the valve s status either open or closed In addition th...

Page 3: ...th the intention of allowing or preventing water from passing through the pipes System specification 1 Opening closing handle 1A Open closed indication 2 Shut Off unit body valve 3 3 4 entry exit adapter 4 Base for a valve not wall mounted 4A Base for a wall mounted valve 5 2XCR123 battery housing ...

Page 4: ...e installed with the handle on top and horizontally placed To provide effective communication ensure to have no more than 12 meters if a wall is present within the structure or 30 meters within an open space structure between the controller and the valve and that the units controller and valve are not positioned within metal cabinets If the above is problematic consider setting up a relay repeater...

Page 5: ...s the range between 0 and 55 degrees centigrade Where there is an apprehension of being hit or damaged In an external place where exposed to rain and direct sunlight and or to the elements the unit should be installed in a watertight plastic casing In humid environment Places where the detector should NOT be positioned ...

Page 6: ...e valve 4 Install the unit on the water line 5 Should a flexible water pipe be required to mount the Shut Off unit on the wall dismantle the base unit 6 Make sure that the Shut Off unit can be opened and closed manually 7 Enable passage of water in the main line and prevent leaks or drippings 8 Ensure easy access to the battery housing 9 If unit wetting is probable install an external protective c...

Page 7: ...on to an alarm system In this case the closure of the valve will be synchronized with the alarm triggering Controller unit 3A 3B 1A 1B 1C 3D 3C 4 5 1A Valve closing button 1B Technician button 1C Valve opening button 3A Water battery indicator 5 5VDC power input 3B Water valve indicator 3C Communications light 3D Voltage indicator 4 Alarm wiring connector ...

Page 8: ...inuous transmission I The four indicators flash 3 times II The voltage indicator flashes III Wait for approximately two minutes by the controller to ensure that the communication indicator is lit continuously in addition to the flashing voltage indicator In case the communication indicator flashes or is turned off a repeater should be installed within the system 3 Press the technician button Contr...

Page 9: ...t the indicator of communication with the valve is lit continuously in addition to the flashing voltage indicator In case the communication indicator flashes or is turned off the systems should be brought closer 3 Hook the controller to the main supply with the transformer Position the controller where measurements indicate qualitative and continuous transmission from the valve and the controller ...

Page 10: ...dicator lights are continuously on voltage valve communication and controller communication 6 Ensure valve indication transfer CONTROL After another thirty seconds the open valve indicator indicates the valve s state open or closed 7 Hook the controller to the main supply with the transformer CONTROL Check that the valve opens and closes accordingly Make sure that the open valve indicator indicate...

Page 11: ...ing at the detector indication light When the indicator light will light up for two consecutive seconds the detector will synchronize itself with the controller III The green detector indicator will flash every minute IV Now you can continue with this procedure to up to 10 detectors per system 3 Conclusion of the flood detector synchronization will be achieved by pressing the valve Open and Close ...

Page 12: ...components Reset of the valve is possible by pressing five consecutive times the technician button in the controller while pressing the Open and Close buttons simultaneously and pressing five consecutive times the technician button in the controller Synchronization reset Hard reset ...

Page 13: ...rk with batteries but by way of electricity transformer 3 The controller should not be connected to an alarm system 4 The positioning of the system s components including of the water valve and controller may be influenced by communication quality factors 5 A repeater should not be installed between the controller and the flood detector Additional clarifications regarding the installation of the f...

Page 14: ...s HARD RESET five times 3 Dismantle the unit from the water line and perform all the stages specified in the disconnection unit installation instruction 4 Synchronize the controller valve system The detectors retain synchronization with the controller Replacement of the disconnection unit valve ...

Page 15: ...ll the control box out of its place 3 Perform all the control unit installation stages 4 Perform a full synchronization process including extraction pause and replacement of the batteries in the valve and full synchronization with all the flood detectors Controller replacement ...

Page 16: ...t two CR123 batteries out of the unit and replace with new ones 2 Verify system synchronization by closing and opening the valve using the controller buttons Replacement of a battery in the Shut Off unit valve ...

Page 17: ... no obstructions in the valve s opening and closing path 2 Open and close the valve using the controller buttons 3 Extract and replace the batteries in the valve and check the fault status 4 Replace the valve 3 Low water battery Valve battery indicator is continuously on Replace the valve battery 4 The circuit does not receive power Voltage indicator is off 1 Check the power connection 2 Replace t...

Page 18: ...quant à un appareil numérique de classe B conformément à la Partie 15 des réglementations de la FCC Ces limites ont été élaborées pour offrir une protection raisonnable contre les interferences nuisibles dans une installation résidentille Cet équipement génère utilize et peut émettre de l énergie de fréquence radio et s il n est pas installé et utilize conformément aux instructions du fabricant pe...

Page 19: ...e received including interference that may cause undesired operation Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est sus...