background image

 

Tripleplus

 

Ltd.

 

|

 

5

 

Hamada

 

St.,

 

High

 

Tech

 

Park,

 

Yoqneam,

 

2069200,

 

Israel

 

|

 

+972

(0)72

2211370

 

|

 

[email protected]

 

|

 

www.tripleplus.io

 

 

Welcome

 

Thank

 

you

 

for

 

choosing

 

 

CLM™

 

(Cloud

 

Leak

 

Management)

 

system

 

designed

 

to

 

detect

 

Water

 

leaks

 

and

 

prevent

 

the

 

subsequent

 

damages.

  

The

 

 

CLM™

 

system

 

will

 

give

 

you

 

peace

 

of

 

mind

 

while

 

at

 

home

 

or

 

away.

 

 

Please

 

note

 

Please

 

read

 

through

 

the

 

instructions

 

carefully

 

and

 

follow

 

the

 

steps

 

of

 

the

 

system's

 

installation.

 

 

Please

 

maintain

 

this

 

document

 

in

 

a

 

safe

 

place

 

for

 

future

 

reference.

  

When

 

in

 

any

 

doubt,

 

contact

 

your

 

authorized

 

distributor

 

or

 

installer.

 

 

Warning!

  

This

 

product

 

was

 

designed

 

to

 

prevent

 

water

 

leaks

 

and

 

as

 

such

 

should

 

be

 

used

 

for

 

water

 

floods

 

only.

 

 

 

CLM™

 

system

 

The

 

 

CLM

TM

 

system

 

detects

 

and

 

prevents

 

water

 

leaks.

 

When

 

the

 

leak

 

is

 

detected,

 

the

 

system

 

disconnects

 

the

 

water

 

supply,

 

wirelessly

 

activating

 

the

 

shutoff

 

units.

   

Each

 

installation

 

can

 

include

 

multiple

 

various

 

detectors

 

and

 

shutoff

 

units

 

installed

 

on

 

water

 

supply

 

pipes.

 

The

 

system

 

is

 

designed

 

to

 

minimize

 

potential

 

flooding

 

damages

 

by

 

shutting

 

down

 

the

 

water

 

supply

 

when

 

the

 

site

 

is

 

inactive

 

and/or

 

when

 

a

 

flooding

 

indication

 

is

 

received.

 

 

The

 

 

CLM™

 

system

 

is

 

designed

 

for

 

internal

 

use

 

and

 

should

 

be

 

installed

 

by

 

an

 

authorized

 

technician.

 

 

Flood

 

detector

 

specification

 

Part

 

No.

 

CLM

FDAMAP

1

00,

 

CLM

FDEMEA

1

00

Product

 

description

 

The

 

flood

 

detectors

 

are

 

to

 

be

 

installed

 

in

 

places

 

probe

 

to

 

water

 

floods

 

or

 

leaks.

  

When

 

a

 

detector

 

detects

 

water

 

flood,

 

a

 

wireless

 

communication

 

is

 

dispatched

 

to

 

initiate

 

closure

 

of

 

the

 

shutoff

 

unit,

 

shutting

 

off

 

the

 

water

 

supply.

  

Dimensions

  

Body

 

98X31X28mm

 

(3.85X1.22X1.1”)

Probe

 

34X16X11mm

 

(1.34X0.63X0.43”)

 

Cable

 

length

 

30cm

 

(1

 

ft.)

 

Weight

  

110gr

 

(0.24Lbs)

Power

 

supply

 

Two

 

AAA

 

non

rechargeable

 

batteries

Operation

 

voltage

 

3V

 

Battery

 

life

 

span

 

Up

 

to

 

two

 

years

Operating

 

RF

 

915

 

MHz

 

Transmission

 

range

 

Open

 

space

 ‐

up

 

to

 

230

 

m

 

(750

 

ft.)

 

When

 

a

 

wall

 

is

 

within

 

the

 

space

 ‐ 

up

 

to

 

120

 

m

 

(390

 

ft.)

 

To

 

avoid

 

damaging

 

the

 

wireless

 

communication,

 

avoid

 

installation

 

within

 

metal

 

cabinets.

 

Working

 

temperature

 

20

 

to

 

+50

0

C

 

(

4

 

to

 

+122

0

F)

 

Certifications

 

FCC

 

ID:2AFOICLMFLD10

 

IC:20798

CLMFLD10

 

 

 

 

 

 

 

 

Flood

 

Detector

 

description

 

1.

 

Indication

 

LED

 

2.

 

Water

 

detector

 

3.

 

Battery

 

housing

 

cover

 

4.

 

Wall

 

mount

 

bracket

 

5.

 

Double

sided

 

adhesive

 

tape

 

application

 

locations

 

(rear)

 

 

 

Flood

 

Detector

 

installation

 

 

1.

 

Open

 

the

 

battery

 

housing

 

cover

 

by

 

pulling

 

it

 

towards

 

the

 

cable,

 

while

 

holding

 

the

 

detector

 

body.

 

2.

 

Remove

 

the

 

cover

 

and

 

expose

 

the

 

battery

 

housing.

 

3.

 

Install

 

2

 

AAA

 

batteries

 

in

 

the

 

battery

 

housing,

 

please

 

note

 

the

 

polarity

 

marking.

 

 

4.

 

Close

 

the

 

battery

 

housing

 

cover.

 

5.

 

Apply

 

the

 

attached

 

double

sided

 

adhesive

 

tape

 

strips

 

to

 

the

 

battery

 

housing

 

cover

 

in

 

the

 

placed

 

defined

 

on

 

the

 

picture.

  

6.

 

Choose

 

the

 

position

 

and

 

height

 

from

 

the

 

floor

 

level

 

most

 

suitable

 

for

 

installation,

 

so

 

during

 

flooding

 

detector’s

 

only

 

electrodes

 

would

 

get

 

wet.

 

Fix

 

both

 

parts

 

of

 

the

 

detector

 

to

 

the

 

wall

 

using

 

the

 

double

 

sided

 

adhesive

 

tape.

 

The

 

bottom

 

part

 

might

 

be

 

fixed

 

using

 

2

 

screws

 

(not

 

attached).

 

Ensure

 

that

 

the

 

box

 

will

 

not

 

be

 

exposed

 

to

 

water.

 

The

 

flood

 

detector

 

contains

 

an

 

electronic

 

circuit

 

and

 

is

 

not

 

within

 

a

 

watertight

 

casing

 

(the

 

two

 

electrodes

 

are

 

the

 

only

 

part

 

that

 

should

 

come

 

in

 

contact

 

with

 

water).

 

7.

 

After

 

the

 

installation,

 

make

 

sure

 

that

 

the

 

indication

 

LED

 

is

 

clearly

 

visible.

 

 

Expected

 

Flood

 

Detector

 

LED

 

behavior

 

 

GREEN

 

blink

 

once

 

in

 

30

 

seconds

 

 

all

 

is

 

OK

 