background image

T R I O N

®

  |   w w w. t r i o n i a q . c o m

Mini M.E.

Mini Mist Eliminator 

Industrial Applications

READ AND SAVE THESE INSTRUCTIONS

Summary of Contents for Mini M.E.

Page 1: ...T R I O N w w w t r i o n i a q c o m Mini M E Mini Mist Eliminator Industrial Applications READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...nitialStart Up 3 IndicatingLight 4 CareandMaintenance 4 General 4 Cleaning 4 Blower MotorAssembly 5 Troubleshooting 5 Diagrams Exploded View Figures 7 Figure 1 Drawing with Drain Line 7 Figure 2 Repla...

Page 3: ...ages as described below and a motor blower An optional inlet plenum is available for ductwork connection The first stage of filtration consists of two aluminum mesh prefilters in series to remove larg...

Page 4: ...des and ordinances Do not connect the unit to the power source until installation is complete Improper electrical installation may damage equipment can create a hazard cause personal injury or death a...

Page 5: ...nded that this unit be disconnected from any electrical supply outlet Failure to follow these precautions could result in electrical shock fire death or serious personal injury as readily and therefor...

Page 6: ...o all electrically charged high voltage components contain electrical interlocks for the safety of operating personnel Always unplug the unit while performing service within the cabinet WARNING RISK O...

Page 7: ...ly light operates intermittently or not at all No Motor operates with little or no air volume from the unit Check for 1 Faulty control switch 2 Motor turns frequently 3 Faulty motor capacitor 4 Loose...

Page 8: ...www trioniaq com Mini M E 7 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l Figure 1 Drawing with Drain Line...

Page 9: ...50 60Hz 3 257680 001 Capacitor 20 F 120V 257680 002 Capacitor 50 F 230V 4 239071 006 Transformer 120V 239071 011 Transformer 230V 5 356764 001 PCB Assembly 6 257544 001 HV Contact Board Assembly 7 132...

Page 10: ...www trioniaq com Mini M E 9 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l Figure 3 Base Unit Outline Drawing...

Page 11: ...www trioniaq com Mini M E 10 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l Figure 4 Outline Drawing with Optional Accessories...

Page 12: ...gure 5 Blower Curves Mini M E EAC 120V 230V 60Hz 0 0 5 1 1 5 2 2 5 0 100 200 300 400 500 600 700 CFM In H 2 O 3 2 Alum Mesh 2 2 Alum Carbon 3 Alum HEPA 2 Alum Carbon HEPA Mini M E EAC 240V 50Hz 0 0 5...

Page 13: ...tered in any way Seller s liability is limited to replacement of defective parts or components and does not include any cost of labor including but not limited to labor required to remove and or reins...

Page 14: ...TRION 101 McNeill Rd Sanford NC 27330 P 800 884 0002 F 800 458 2379 www trioniaq com customerservice trioniaq com TRION 2015 All Rights Reserved Form No 157550 001 Rev 11 15...