the upper edge of the humidifier against the duct so that the 

mounting holes line up with the drilled holes on the duct.  

Secure the humidifier with two #8 X 3/4” self-drilling sheet 

metal screws from the accessory bag.

6.  Refer to the section regarding pad replacement on page 8.  

Complete that section before proceeding to ensure that the 

internal components of the humidifier are properly aligned/

installed as they may have become misaligned during 
shipment.  Failure to complete this task may result in 
faulty operation or leaks.

7. 

Ensure  that  the  humidifier  is  level  and  plumb  before 

proceeding.

4.3 Plumbing

1.  Install a saddle valve and strainer (not provided) on the 

nearest  cold water supply pipe.  Hot water will cause 
improper operation. 
(See the instructions that accompany 
the saddle valve for additional details.)

2.  After the saddle valve and strainer are installed but before 

inserting the line into the humidifier supply fitting, turn the 

saddle valve to the open position and discharge the water 

into  a  bucket  or  pan.    This  will  allow  the  water  to  flush 

any debris that may have accumulated in the line during 

the installation process.  Once this is complete, close the 

saddle valve.

3. 

Attach the line to the humidifier by simply pushing the line 

into the push-to-lock fitting and pulling back slightly to seat 

the line.  If it becomes necessary to remove the line, press 

on the release ring around where the line goes into the 

fitting to release the line and pull it out.  See Figure 5 for 

plumbing diagram.

4. 

Connect the drain hose to the drain connection fitting and 

run this to an open, gravity drain.  The end of this line must 

not be submerged in water or be trapped.

5.  Turn on the saddle valve.
6. 

Ensure  that  no  water  is  leaking  from  any  of  the  fittings 

before proceeding.

4.4 Electrical

The ComfortBREEZE

 CB300/CB300S humidifier requires a 24 

VAC source of electrical power that may be taken from the HVAC 
system terminals.   In order to access the wiring compartment 

press the release pads, as shown in Figure 6, and pull the cover 

off toward you. 

4.4.1 Wiring Model CB300 (without water saving controls)

VALVE

SOLENOID

HUMIDISTAT

MANUAL

SWITCH

AIR PROVING

24 VAC

TRANSFORMER

CIRCUIT

FURNACE BLOWER

120 VAC FROM

Refer to Figure 7.  Install the 24 Volt transformer from a source 
of 120VAC power that is only powered when the furnace fan 
is energized.  The transformer will supply 24 VAC through the 
humidistat and air proving switch (not included) and energize 
the water solenoid valve upon a call-for-humidity.  

Figure 6

Figure 5

Figure 7

Drain hose to condensate pump  

or open floor drain. No trap.

Summary of Contents for ComfortBREEZE CB300

Page 1: ...T R I O N w w w t r i o n i a q c o m ComfortBREEZE TM CB300 CB300S Flow Through Evaporative Humidifier READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...ox 4 3 3 Unit Specifications 4 4 Installation 4 4 1 Clearances 5 4 2 Mounting 5 4 3 Plumbing 6 4 4 Electrical Wiring 6 4 4 1 Wiring CB300 without water saving controls 6 4 4 2 Wiring CB300S with H2OSm...

Page 3: ...rts or components and does not include the payment of the cost of labor charges to remove or replace such defective components or parts 7 TRION will not be responsible for loss of use of any product l...

Page 4: ...A lower setting may be necessary to prevent condensation on windows during the coldest part of the winter An electronic humidistat is supplied with CB300S units that can automatically adjust the setp...

Page 5: ...30 40 relative humidity If condensation occurs on windows the humidistat setting must be lowered to prevent condensation damage DO NOT install the humidifier where freezing temperatures may occur DO...

Page 6: ...rocess Once this is complete close the saddle valve 3 Attach the line to the humidifier by simply pushing the line into the push to lock fitting and pulling back slightly to seat the line If it become...

Page 7: ...Typical furnace bonnet temperature is nominally 120 F DIP 4 Furnace Runs Fan Humidifier Runs Fan In most systems the HVAC system operates the main blower The CB300S has a 24VAC output that may be used...

Page 8: ...humidity only during a call for heat DIP Switch 3 Off DIP Switch 4 Off Air Proving Switch Required Go Terminal No Connection W G Terminal No Connection Heat Pump System Humidifier operates upon a cal...

Page 9: ...unit will not operate until airflow is present 2 Slow Red Blink Once the solenoid valve is energized and humidification has begun the controls must see a change in temperature or the unit will not be...

Page 10: ...hat there is power supplied to the valve Check control board output Circuit Board has failed fuse is blown Replace circuit board LED is glowing solid RED Service Timer has expired Replace the humidifi...

Page 11: ...300 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 11 www trioniaq com 7 Exploded Views Parts List 7 1 CB300S Exploded View 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 19 20...

Page 12: ...rtBREEZE TM Model CB300 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 12 www trioniaq com 7 2 CB300 Exploded View 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Figur...

Page 13: ...ID VALVE ASSEMBLY 1 8 265508 002 CONTROL BOARD CB300S 2 2 11 265698 001 PNEUMATIC PUSH TO CONNECT FITTING 1 12 G 128 FLUID RESTRICTOR 1 12 G 217 FLUID RESTRICTOR 1 1 14 265470 001 PAD EVAPORATOR 1 15...

Page 14: ...Form No 265817 001 Rev 11 15 TRION 2015 All Rights Reserved TRION 101 McNeill Rd Sanford NC 27330 P 800 884 0002 F 800 458 2379 www trioniaq com customerservice trioniaq com...