background image

C o m f o r t

B R E E Z E  

T M

  M o d e l   C B 3 0 0

I n s t a l l a t i o n ,   O p e r a t i o n ,   &   M a i n t e n a n c e   M a n u a l

3

w w w. t r i o n i a q . c o m

1. Warranty

Humidifier 5-Year Limited Warranty

This  limited  warranty  covers  TRION  Residential  Type  Humidifiers, 

excluding duct work, wiring and installation. TRION warrants that all new 

TRION humidifiers are free from defects in material and workmanship 

under normal, non-commercial use and service. TRION will remedy any 

covered defects if they appear within 60 months from the date of original 

installation & subject to the terms and conditions of this Limited 5-Year 

Warranty stated below:

1. 

THIS  LIMITED  5-YEAR  WARRANTY  is  granted  by  TRION 

Customer Service, 101 McNeill Road, Sanford, NC 27330.

2. 

This warranty shall extend only to any non-commercial owner who 

has purchased the residential humidifier other than for purposes 

of resale.

3. 

All components are covered by this limited warranty except 

expendable  items,  such  as  evaporative  pads,  media  filter  pads 

and nozzles.

4. 

If, within the warranty period, any TRION residential humidifier unit 

or component requires service it must be performed by a competent 
heating and/or air conditioning contractor (preferably the installing 

contractor). TRION will not pay shipping charges, or labor charges 

to remove or replace such defective parts or components. If the 
part or component is found by inspection to contain such defective 
material and workmanship it will be either repaired or exchanged 

free of charge at TRION’s option, and returned freight collect.

5. 

In order to obtain the benefits of this limited 5-year warranty, the 

owner must notify the dealer or distributor of any defect within 30 
days of its discovery. If after reasonable time you have not received 

an adequate response from the dealer or distributor, notify in writing 

to  TRION  Customer  Service  101  McNeill  Road,  Sanford,  NC 

27330, or call 1-800-884-0002 or email customerservice@trioniaq.

com Humidifiers which have been installed or become part of real 

estate cannot be returned. TRION will receive, freight prepaid, only 

removable parts or components of such defective humidifiers.

6. 

This limited warranty does not apply to any part or component 

that  is  damaged  in  transit  or  in  handling,  has  been  subject  to 

misuse, neglect or accident; has not been installed, operated and 

serviced  according  to  TRION’s  instructions;  has  been  operated 

beyond the factory rated capacity; or altered in any such way that 

its performance is affected. There is no warranty due to neglect, 

alteration or ordinary wear and tear. TRION’s liability is limited to 
replacement of defective parts or components and does not include 
the payment of the cost of labor charges to remove or replace such 
defective components or parts.

7. 

TRION  will  not  be  responsible  for  loss  of  use  of  any  product; 

loss  of  time,  inconvenience,  or  any  other  indirect,  incidental  or 

consequential damages with respect to person or property, whether 

as  a  result  of  breach  of  warranty,  neglect  or  otherwise.  SOME 

STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION 

OF  INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES,  SO  THE 

LIMITATION OR EXCLUSION IN THE PRECEDING SENTENCE 

MAY NOT APPLY TO YOU. 

8. 

THIS  WARRANTY  GIVES  YOU  SPECIFIC  RIGHTS, AND  YOU 

MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE 

TO STATE.

9. 

Any warranty by TRION of merchantability, fitness for use or any 

other  warranty  (express,  implied  or  statutory),  representation  or 

guarantee  other  than  those  set  forth  herein,  shall  expire  at  the 

expiration date of this express limited warranty. SOME STATES 
DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED 

WARRANTY LASTS, SO THE LIMITATION IN THE PRECEDING 

SENTENCE MAY NOT APPLY TO YOU.

10.  TRION reserves the right to make changes in the design and 

material of its products without incurring any obligation to 
incorporate such changes in units completed on the effective date 
of such change.

2. Safety & Warnings

!

DANGER

RISK OF ELECTRIC SHOCK

Before cleaning, servicing, or parts replacement, the unit must 

be disconnected from all sources of electricity.

!

WARNING

Improper  installation,  adjustment,  alteration,  service, 
or  maintenance  may  cause  property  damage,  injury,  or 

death.  This appliance must be installed according to these 

instructions.  Read these instructions thoroughly before 

installing or servicing the unit.

!

CAUTION

Read these instructions thoroughly before installing this unit.  

Check  data  label  and  verify  electrical  specifications  agree 

with those at the point of installation.

!

WARNING

Failure to install this unit in a position that is level and plumb 

may impair the unit’s ability to drain if an overflow condition 

presents itself.  Damage to personal property may also result.

!

WARNING

Installation in freezing conditions can result in unit failure. 

Damage to personal property may also result.  

!

WARNING

A drain pan should be installed under the unit and any supply 

water / drain connections to prevent damage to property in the 

event of a water leak or faulty operation.

!

CAUTION

TRION  recommends  that  this  humidifier  be  installed  by  a 

trained HVAC professional.  Do not connect the unit to the 

power source until the installation is complete.  A thorough 

checkout of the unit installation should be completed before 

operating the unit.  Failure to follow these directions may void 

the manufacturer’s original warranty.

!

WARNING

Electrical power to the furnace must be disconnected before 

proceeding. Serious injury or death may result.

Summary of Contents for ComfortBREEZE CB300

Page 1: ...T R I O N w w w t r i o n i a q c o m ComfortBREEZE TM CB300 CB300S Flow Through Evaporative Humidifier READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...ox 4 3 3 Unit Specifications 4 4 Installation 4 4 1 Clearances 5 4 2 Mounting 5 4 3 Plumbing 6 4 4 Electrical Wiring 6 4 4 1 Wiring CB300 without water saving controls 6 4 4 2 Wiring CB300S with H2OSm...

Page 3: ...rts or components and does not include the payment of the cost of labor charges to remove or replace such defective components or parts 7 TRION will not be responsible for loss of use of any product l...

Page 4: ...A lower setting may be necessary to prevent condensation on windows during the coldest part of the winter An electronic humidistat is supplied with CB300S units that can automatically adjust the setp...

Page 5: ...30 40 relative humidity If condensation occurs on windows the humidistat setting must be lowered to prevent condensation damage DO NOT install the humidifier where freezing temperatures may occur DO...

Page 6: ...rocess Once this is complete close the saddle valve 3 Attach the line to the humidifier by simply pushing the line into the push to lock fitting and pulling back slightly to seat the line If it become...

Page 7: ...Typical furnace bonnet temperature is nominally 120 F DIP 4 Furnace Runs Fan Humidifier Runs Fan In most systems the HVAC system operates the main blower The CB300S has a 24VAC output that may be used...

Page 8: ...humidity only during a call for heat DIP Switch 3 Off DIP Switch 4 Off Air Proving Switch Required Go Terminal No Connection W G Terminal No Connection Heat Pump System Humidifier operates upon a cal...

Page 9: ...unit will not operate until airflow is present 2 Slow Red Blink Once the solenoid valve is energized and humidification has begun the controls must see a change in temperature or the unit will not be...

Page 10: ...hat there is power supplied to the valve Check control board output Circuit Board has failed fuse is blown Replace circuit board LED is glowing solid RED Service Timer has expired Replace the humidifi...

Page 11: ...300 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 11 www trioniaq com 7 Exploded Views Parts List 7 1 CB300S Exploded View 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 19 20...

Page 12: ...rtBREEZE TM Model CB300 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 12 www trioniaq com 7 2 CB300 Exploded View 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Figur...

Page 13: ...ID VALVE ASSEMBLY 1 8 265508 002 CONTROL BOARD CB300S 2 2 11 265698 001 PNEUMATIC PUSH TO CONNECT FITTING 1 12 G 128 FLUID RESTRICTOR 1 12 G 217 FLUID RESTRICTOR 1 1 14 265470 001 PAD EVAPORATOR 1 15...

Page 14: ...Form No 265817 001 Rev 11 15 TRION 2015 All Rights Reserved TRION 101 McNeill Rd Sanford NC 27330 P 800 884 0002 F 800 458 2379 www trioniaq com customerservice trioniaq com...

Reviews: