background image

C o m f o r t

B R E E Z E  

T M

  M o d e l   C B 3 0 0

I n s t a l l a t i o n ,   O p e r a t i o n ,   &   M a i n t e n a n c e   M a n u a l

13

w w w. t r i o n i a q . c o m

265686-002 / CB300 

without circuit board

265686-001 / CB300S 

with H

2

OSmart™ 

Controls

ITEM

TRION P/N

DESCRIPTION

1

1

1

265456-001

COMFORTBREEZE FILTER RETAINER

1

1

2

265455-001

COMFORTBREEZE DRAIN TRAY

2

2

3

265464-001

BY-PASS SIDE PANEL W/DUCT

1

1

4

465466-001

BY-PASS DIVIDER

1

1

5

265469-001

BY-PASS DOME

-

1

6

265457-001

ASS'Y-DISTRIBUTION TUBE 18 HOLE

1

-

6

265457-002

ASS'Y-DISTRIBUTION TUBE 6 HOLE

1

1

7

G-109

G-109 SOLENOID VALVE ASSEMBLY

-

1

8

265508-002

CONTROL BOARD, CB300S

2

2

11

265698-001

PNEUMATIC PUSH-TO-CONNECT FITTING

-

1

12

G-128

FLUID RESTRICTOR

1

-

12

G-217

FLUID RESTRICTOR

1

1

14

265470-001

PAD - EVAPORATOR

-

1

15

266180-001

THERMISTOR ASSEMBLY, APPROX. 9"

-

1

16

266180-002

THERMISTOR ASSEMBLY, APPROX. 19.5"

-

1

17

266158-001

CABLE CLIP

1

1

18

465498-001

DAMPER COLLAR

1

1

19

265467-001

BY-PASS DAMPER

1

1

20

265468-001

BY-PASS KNOB - DAMPER 

1

1

21

265796-001

COMPRESSION SPRING 

1

1

22

465499-001

COLLAR BLANK 

-

1

23

265160-002

HUMIDISTAT, ELECTRONIC

1

-

23

265160-001

HUMIDISTAT, MECHANICAL

1

1

24

153296-006

TUBING - 1/4" O.D. X 16.5" LG"

-

1

25

266249-001

THERMISTOR BRACKET

1

1

26

266256-001

MAIN BASE DRILL DETAIL, CB300

1

-

27

63667

TRANSFORMER - 120V-24V  (Not Shown)

7.3 Parts List

Summary of Contents for ComfortBREEZE CB300

Page 1: ...T R I O N w w w t r i o n i a q c o m ComfortBREEZE TM CB300 CB300S Flow Through Evaporative Humidifier READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...ox 4 3 3 Unit Specifications 4 4 Installation 4 4 1 Clearances 5 4 2 Mounting 5 4 3 Plumbing 6 4 4 Electrical Wiring 6 4 4 1 Wiring CB300 without water saving controls 6 4 4 2 Wiring CB300S with H2OSm...

Page 3: ...rts or components and does not include the payment of the cost of labor charges to remove or replace such defective components or parts 7 TRION will not be responsible for loss of use of any product l...

Page 4: ...A lower setting may be necessary to prevent condensation on windows during the coldest part of the winter An electronic humidistat is supplied with CB300S units that can automatically adjust the setp...

Page 5: ...30 40 relative humidity If condensation occurs on windows the humidistat setting must be lowered to prevent condensation damage DO NOT install the humidifier where freezing temperatures may occur DO...

Page 6: ...rocess Once this is complete close the saddle valve 3 Attach the line to the humidifier by simply pushing the line into the push to lock fitting and pulling back slightly to seat the line If it become...

Page 7: ...Typical furnace bonnet temperature is nominally 120 F DIP 4 Furnace Runs Fan Humidifier Runs Fan In most systems the HVAC system operates the main blower The CB300S has a 24VAC output that may be used...

Page 8: ...humidity only during a call for heat DIP Switch 3 Off DIP Switch 4 Off Air Proving Switch Required Go Terminal No Connection W G Terminal No Connection Heat Pump System Humidifier operates upon a cal...

Page 9: ...unit will not operate until airflow is present 2 Slow Red Blink Once the solenoid valve is energized and humidification has begun the controls must see a change in temperature or the unit will not be...

Page 10: ...hat there is power supplied to the valve Check control board output Circuit Board has failed fuse is blown Replace circuit board LED is glowing solid RED Service Timer has expired Replace the humidifi...

Page 11: ...300 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 11 www trioniaq com 7 Exploded Views Parts List 7 1 CB300S Exploded View 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 19 20...

Page 12: ...rtBREEZE TM Model CB300 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 12 www trioniaq com 7 2 CB300 Exploded View 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Figur...

Page 13: ...ID VALVE ASSEMBLY 1 8 265508 002 CONTROL BOARD CB300S 2 2 11 265698 001 PNEUMATIC PUSH TO CONNECT FITTING 1 12 G 128 FLUID RESTRICTOR 1 12 G 217 FLUID RESTRICTOR 1 1 14 265470 001 PAD EVAPORATOR 1 15...

Page 14: ...Form No 265817 001 Rev 11 15 TRION 2015 All Rights Reserved TRION 101 McNeill Rd Sanford NC 27330 P 800 884 0002 F 800 458 2379 www trioniaq com customerservice trioniaq com...

Reviews: