background image

T R I O N

®

  |   w w w. t r i o n i a q . c o m

Air Boss

®

 Model 38 Series

Industrial Mist Precipitator

READ AND SAVE THESE INSTRUCTIONS

Installation  

Operation

Maintenance

Parts

Manual

Summary of Contents for Air Boss 38 Series

Page 1: ...T R I O N w w w t r i o n i a q c o m Air Boss Model 38 Series Industrial Mist Precipitator READ AND SAVE THESE INSTRUCTIONS Installation Operation Maintenance Parts Manual...

Page 2: ...4 III Operation 4 IV Maintenance 5 V Troubleshooting 5 VI Recommended Spare Parts 6 VII Outline Drawings 150 CFM Parts 7 150 CFM Outline Drawing with Inlet Flange or Pipe 424396 8 150 CFM Outline Draw...

Page 3: ...ted on the discharge side of the collector section provides protection especially on units installed with an open discharge The baffle also slides into the cabinet like a drawer All three of these com...

Page 4: ...l Place in safe location being careful not to deform the high voltage spring contacts in the under side 3 Remove flame arrestor ionizer collector and outlet baffle and place them aside with access pan...

Page 5: ...checked Access to the power supply is gained by removing the primary power cable and power pack cover V TROUBLESHOOTING NOTE EXERCISE THE NORMAL PRECAUTIONS WHEN WORKING WITH HIGH VOLTAGE A PILOT LIGH...

Page 6: ...ionizer current should be between 0 5 and 1 5 mA 5 Loose or faulty high voltage connection between power supply and ionizer collector elements Check secondary wiring from power supply to high voltage...

Page 7: ...0 0 1 060 059 183 6 Flange 6 Flange 322791 001 1 0 0 1 150 CFM PARTS NOTES 1 The part number for the Ionizer Cell for all units on this page is 422728 011 Only one required 2 The part number for the C...

Page 8: ...Model 38 Series I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 8 www trioniaq com 150 CFM Outline Drawing with Inlet Flange or Pipe 424396...

Page 9: ...Model 38 Series I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 9 www trioniaq com 150 CFM Outline Drawing with Inlet Outlet Flange or Pipe 424397...

Page 10: ...8 046 153 2 Pipe _ 322792 001 1 0 0 1 019 047 156 3 Pipe _ 322792 002 1 0 0 1 020 048 158 4 Pipe _ 322791 002 1 0 0 1 021 049 164 6 Pipe _ 322790 001 1 0 0 1 025 053 156 2 Pipe 2 Pipe 322792 001 1 0 0...

Page 11: ...Model 38 Series I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 11 www trioniaq com 300 CFM Outline Drawing with Inlet Flange or Pipe 424399...

Page 12: ...Model 38 Series I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 12 www trioniaq com 300 CFM Outline Drawing with Inlet Outlet Flange or Pipe 424398...

Page 13: ...tor Part Number Flame Arrestor Power Supply 120 240 VAC VAC 439057 063 355 8 Flange 8 Flange 322791 003 1 0 439057 064 355 8 Flange 8 Flange 322791 003 0 1 600 CFM PARTS NOTE 1 The part number for the...

Page 14: ...Model 38 Series I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 14 www trioniaq com 600 CFM Outline Drawing 429436...

Page 15: ...ONIZER BLK WHT IONIZER BLK GRN WHT 120V 50 60 HZ 1 LINE GROUND NEUTRAL BLK RED LED 120VAC CATHODE ANODE NEUT GRD POWER SUPPLY RED BLACK BLK WHT BOX MOUNTING RECEPTACLE PRIMARY LEAD AND PLUG ASSY ENCLO...

Page 16: ...nd 300 CFM 268678 003 Primary Plug and Receptacle Assembly 240 VAC Input Voltage 150 and 300 CFM 1 268678 002 Primary Plug and Receptacle Assembly 120 VAC Input Voltage 600 CFM 268678 004 Primary Plug...

Page 17: ...Model 38 Series I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 17 www trioniaq com V DIAGRAM 3 6 5 1 4 2...

Page 18: ...Form No 61 0184 Rev 10 16 TRION 2016 All Rights Reserved TRION 101 McNeill Rd Sanford NC 27330 P 800 884 0002 F 800 458 2379 www trioniaq com customerservice trioniaq com...

Reviews: