![Trinamic TMCM-343 Hardware Manual Download Page 22](http://html1.mh-extra.com/html/trinamic/tmcm-343/tmcm-343_hardware-manual_1163077022.webp)
TMCM-343 Hardware Manual (V1.07 / 2011-JUN-08)
22
Copyright © 2011, TRINAMIC Motion Control GmbH & Co. KG
9
Migrating from the TMCM-303 to the
TMCM-343
Migrating TMCM-303 applications to the TMCM-343 is easy, as the TMCM-343 can replace a TMCM-303
without problems. The connector of the TMCM-343 is identical to the connector of the TMCM-303, so
that a TMCM-343 can just be plugged into the slot for a TMCM-303 (it can also use the same base
boards as the TMCM-303). Also the TMCL™ firmware of the TMCM-343 is highly compatible with the
TMCM-303.
However there are some slight differences that have to be observed (due to the fact that the TMCM-
343 has some enhancements compared to the TMCM-303):
Speed of TMCL™ program execution: TMCL™ programs run up twenty times faster than on the
TMCM-303 module. In general, the developer of a TMCL™ program should not make
assumptions about command execution times.
Axis parameters 6 and 7 (run current and stand by current): The range of these parameters is
now 0… 255 and no longer 0… 1500. These parameter settings must be adapted.
Axis parameters 194 and 195: The reference search speeds are now specified directly (1… 2047)
and no longer as fractions of the maximum positioning speed. These settings have to be
adapted.
MVP COORD: The parameter of the MVP COORD command is different (to make it compatible
with the six axis modules). Please see the TMCM-341/342/343 TMCL™ Firmware Manual for
details. The usage of the MVP COORD command also has to be adapted.
Default CAN bit rate: the default CAN bit rate of the TMCM-343 module (e.g. after resetting it
to factory default settings) is 1000kBit/s (in contrast to 250kBit/s on the TMCM-303.
All other TMCL™ commands and parameters are the same as with the TMCM-303.