TMCM-1160 CANopen® Firmware Manual • Firmware Version V3.20 | Document Revision V2.10 • 2019-JAN-04
89 / 110
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
rw
see CiA402-3
SIGNED32
0
Table 271: Entry Description (60FF
h
)
8.2
How to move a Motor in pv Mode
Here is a little example that shows how to get a motor running in pv mode. In this little example we assume
that the module has been reset (and then switched to pre-operational or operational) by NMT commands
before.
• If you do not have any limit switches connected, first disable the limit switch inputs by writing 3 to
object 2005
h
.
• Select pv mode by writing 3 to object 6060
h
.
• Write 6 to object 6040
h
to switch to READY_TO_SWITCH_ON state.
• Write 7 to object 6040
h
to switch to SWITCHED_ON state.
• Write 15 to object 6040
h
to switch to OPERATION_ENABLED state.
• Write the desired target speed (e.g. 1000) to object 60FF
h
. The motor now accelerates to that speed.
• Stop the motor by writing 0 to object 60FF
h
.
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany