TMCM-1160 CANopen® Firmware Manual • Firmware Version V3.20 | Document Revision V2.10 • 2019-JAN-04
88 / 110
In profile velocity mode, this object also sets the deceleration to be used (the deceleration ramp is always
the same as the acceleration ramp in pv mode).
Object Description
Index
Name
Object Type
Data Type
6083
h
Profile Acceleration
Variable
SIGNED32
Table 266: Object Description (6083
h
)
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
rw
no
SIGNED32
0
Table 267: Entry Description (6083
h
)
8.1.10
Object 6085
h
: Quick Stop Deceleration
This object indicates the configured deceleration used to stop the motor when the quick stop function is
activated and the quick stop code object 605A
h
is set to 2 (or 6). The value is given in the same unit as
profile acceleration object 6083
h
.
Object Description
Index
Name
Object Type
Data Type
6085
h
Quick stop deceleration
Variable
UNSIGNED32
Table 268: Object Description (6085
h
)
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
rw
no
UNSIGNED32
51200
Table 269: Entry Description (6085
h
)
8.1.11
Object 60FF
h
: Target Velocity
This object indicates the configured target velocity and is used as input for the trajectory generator. Object
60FF
h
sets the target velocity when using profile velocity mode. The drive then accelerates or decelerates
to that velocity using the acceleration and deceleration set by objects 6083
h
and 6084
h
. The values are
given in units which can be selected with object 208C
h
, described in section
Object Description
Index
Name
Object Type
Data Type
60FF
h
Target Velocity
Variable
SIGNED32
Table 270: Object Description (60FF
h
)
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany