4.2.4
Gate jumpers LU, HU, J10, J7, etc
Connects the TMC389 gate driver outputs to the MOSFETs
Setting
Function Description
1-2
normal
operation
MOSFET gate controlled by TMC389
2-3
external
load
Gate driver signal available at test load output (C12, C15, etc.)
4.2.5
Bridge center sense jumpers BMU, BMV, BMW, J1, 2, J4
Connects the bridge outputs to TMC389 BR pins
Setting
Function Description
1-2
normal
TMC389 sees the bride center points
open
BM open This setting allows testing of the short to GND condition without
shorting the bridge output.
4.2.6
Erase Jumper J14
Erases the CPU
Setting
Function Description
1-2
Erase
Attention:
Erases the processor. Reprogram it via RS232 using the
SAMBA tool.
open
operation