![Trinamic PDx-013-42 Hardware Manual Download Page 19](http://html.mh-extra.com/html/trinamic/pdx-013-42/pdx-013-42_hardware-manual_1163082019.webp)
PD-013-42 / TMCM-110-42 Manual (V1.24/2011-NOV-25)
19
Copyright © 2011, TRINAMIC Motion Control GmbH & Co. KG
The maximum step input frequency is 350kHz, aligned to the Direction signal. The minimum logic
0
time is
0.7 µs and the minimum logic
1
time is 2.0 µs. A step is triggered by the positive going edge of the signal
(switching off of optocoupler).
Function Table:
Extern
GND
open wire
V
COM
= 5… 24V
Intern
HIGH
LOW
step pulse
direction
0.7µs min
2.0µs min
0.7µs min
t
DIRHOLD
t
DIRSETUP
Figure 7.4: Step and Direction Signal
7.5
Firmware update
Start the program TMCM013boot.exe for the firmware update (available on
):
Figure 7.5: Firmware update tool
-
Choose your RS485 connection.
-
Select your Module ID (default is A).
-
Load the new firmware file (e.g. TMCM013_V1.08.hex), to download from
-
Start the update process.
Check your firmware version at the end of the update process with command
AX
.