background image

Tourmaline 

1120

INSTALLATION INSTRUCTION

GBR-IRL

Summary of Contents for Tourmaline 1120

Page 1: ...Tourmaline 1120 INSTALLATION INSTRUCTION GBR IRL...

Page 2: ...MESH AND DISPERSION MEDIUM 8 4 TECHNICAL DETAILS MAXITROL GV60 10 5 INSTRUCTIONS FOR MAXITROL GV60 11 6 GAS TECHNICAL SPECIFICATIONS 12 7 CONCENTRIC PATHWAYS 14 8 CONCENTRIC FLUE SYSTEM 15 8 1 Compon...

Page 3: ...d from the glass panel using a glass cleaner made specifically for fireplaces Distance to flammable materials Maintain the following minimum distances from combustible materials front 1000mm side 500m...

Page 4: ...ppliance functions operate correctly The gas supply should only be connected up when the electricity supply is disconnected Failing to do so may cause damage to the gas control equipment 2 3 Removing...

Page 5: ...side glass panels 1 These strips are fixed with magnets and can be removed from the bottom to the front Loosen the four bolts per glass panel two under 2 and two behind 3 but do not remove them Remove...

Page 6: ...ast the contact surface of the front glass panel 3 Clamp the side glass panel s by tightening the glass holder screws or fitting the spring glass holder Make sure the seals are complete whole and clea...

Page 7: ...The restrictor 7 1 and or baffle plate 2 can be mounted inside the appliance at the location of the flue gas duct Chapter 7 Concentric pathways contains a table that describes when a baffle plate and...

Page 8: ...rille Remove the right burner 2 Distribute the glass granules evenly over the middle part of the grille Place the middle log A on the horizontal burner 3 Fit the right part of the grille Place the coa...

Page 9: ...3 5 2 4 6 A A B B B F G Trimline Tourmaline Installation instruction 9...

Page 10: ...ght burner 5 Gasuitlaat voorste brander middenbranders 6 Multi cable 7 Piezo connection 8 Connector double burner 9 Receiver Appliance category C11 C31 C91 Pilot flame SIT 3 flames Security Thermocoup...

Page 11: ...unresponsive to commands from the handset NOTE Do not tighten the contact breaker and the thermocouple connection too tightly on the gas valve It is sufficient to tighten by hand and add a half a tur...

Page 12: ...No With mechanical control of room temperature by thermostat No With electronic control of room temperature Yes With electronic control of room temperature plus day time switch Yes With electronic co...

Page 13: ...stage heat output no room temperature control No 2 or more manually adjustable stages no control of the room temperature No With mechanical control of room temperature by thermostat No With electronic...

Page 14: ...ngth 1 metres 90 Bend calculation length 2 metres Length including roof or exterior wall outlets Always adhere to a starting length of 1 metre Ratio vertical horizontal X X1 X2 Y 2 1 Ratio vertical ho...

Page 15: ...gh through a refractory fa ade The flue should be encased if necessary Even if the flue is to be installed along non refractory materials sufficient fire resistant measures must be taken Determine the...

Page 16: ...ting plate to the flexible hose on the roof 7 clamp it with a hose bracket Stainless steel 90 to 165 secure the whole with Parker screws Attach the mounting plate to the chimney coping watertight on t...

Page 17: ...Under a carport roof or balcony inside and outside corners 500 G From ground level and rainwater drainage pipes 300 H Inside and outside a corner 500 I Above an external gas pressure regulator 1000 S...

Page 18: ...ied out on 1 Seal of the exhaust and supply circuit 2 Seal of the upper and lower pressure release hatches of the appliance check the gasket 3 The operation of the pressure release hatches that they c...

Page 19: ...ble detergent surfactant We recommend our thermCet Cleaner set Important After the first use there will be a white haze on the inside of the glass pane this white haze must be removed immediately afte...

Page 20: ...r the LED module power supply in the vicinity of the appliance 11 2 Fitting the glass plate Remove the front glass panel Paragraph 2 3 Removing the front glass panel Remove the right hand part of the...

Page 21: ...n medium see Chapter 3 Installation of the burner mesh and dispersion medium Fit the front glass panel See Paragraph 2 5 Fitting the front glass panel 11 3 Fitting the LED unit The LED unit can be mou...

Page 22: ...w drops down Place the LED module 4 on the mounting plate using the screws supplied Connect the cable to the receiver 6 Connect the mains adapter to the receiver 5 and the 230 VAC wall socket Check wh...

Page 23: ...metal Check whether cable is free of metal parts Poor spark candle Check spark candle for fractures replace if necessary Distance of sparkling candle to pilot flame head Check distance is approximate...

Page 24: ...flame should be free of obstructions Small lazy pilot flame Check and correct pressure and physical state of pilot flame burner Close main burner flame openings Check and clean with a vacuum cleaner o...

Page 25: ...1144 221 422 151 491 502 500 150 100 175 370 min 500 min 100 Trimline Tourmaline Installation instruction 25 Appendix 1 DIMENSIONAL DRAWINGS Trimline Tourmaline Measurements in mm...

Page 26: ...s or stoves with a closed combustion system Chimney mounting plate Renovation package Existing flue Clamping strap Roof pass through Clamping strap Interior mounting plate Renovation package Sliding e...