To delete access codes
8. After the 3/4 key is pressed (step 3 above), if there are no access codes stored in
memory, the keypad beeps for 2 seconds and returns to step 3 above. If there are
stored codes, the keypad beeps twice.
9. Enter the 4-digit code you wish to delete. If the code does not match a stored code, the
keypad beeps for 2 seconds and returns to step 3 above. If the code entered does
match a stored code, the keypad beeps twice.
10. Enter the 4-digit code you wish to delete a second time. If it matches the first entry, the
keypad beeps 4 times to confirm the code has been removed from the valid access
code list. If the code entered the second time does not match the first entry, the keypad
beeps for 2 seconds, and returns to step 3 above.
To delete all user access codes
11. After the 3/4 key is pressed (step 3 above) the keypad beeps twice. Instead of entering
a code you wish to delete, press the 1/2 and 9/0 buttons simultaneously
12. The keypad beeps twice, release both buttons
13. The authority code must be entered next, entering the wrong code will cause a 2
second beep, and the keypad returns to step 3 above
14. After the correct authority code is entered, the keypad beeps four times indicating all
user codes have been erased, and returns to step 3 above
To exit the keypad learn mode, press the 9/0 button. The keypad will beep twice and the
backlight blinking will stop. If at any time there is 60 seconds of no button activity, learn mode
will exit.
Keypad Anti-Tamper Lockout Mode
After repeated attempts to enter codes (5 invalid user codes), the keypad plays a 2 second
error beep and enters an inactive mode that disables buttons for 1 minute. The lock indicator
flashes red and amber during this state. This helps prevent undesired access by entering
random codes. No beep will sound with button press while the system is in the disabled state.
Alarm
Arming sequence:
Arming the alarm requires that all the following conditions are true.
•
The Ignition must be “Off”
•
Entrance door must be closed, Door ajar input J1P11 is inactive (not grounded)
•
Entrance door must be locked, Entrance door key switch J1P8 is inactive (not grounded)
After locking all and a delay of 10 seconds, and the above conditions are met, the system is
armed and the anti-theft LED (J2P7) blinks periodically.
If the alarm fails to activate, the only indication it is not armed is the anti-theft LED will not
blink.
Full security triggers: any of the following conditions will trip the alarm:
•
The Ignition is turned “On”