www.trilithic.com
Page IV-131
180 DSP Operation Manual
Signal Level Meter
Ping Mode
When the
Ping
mode is selected, the
following measurement results are
displayed as shown in the image to the
right:
• Minimum Time
- This is the
minimum time required to send/
receive a single test packet.
• Average Time
- This is the average
time required to send/receive all
test packets.
• Maximum Time
- This is the maximum time required to send/receive a single test
packet.
• Sent
- This is the number of packets sent by the 180 DSP to the destination IP
address.
• Received
- This is the number of packets received by the 180 DSP from the
destination IP address.
• LPR
- This is the lost packet ratio. This measurement is displayed in the bar graph
and as a numeric value. The LPR is calculated as the percentage of packets
received to those which were sent (LPR = {Received Packets / Sent Packets} *
100%), for example:
• 50 sent packets
• 25 received packets
• LPR = {25 / 50} * 100%
{0.50} * 100%
50%
Summary of Contents for 180 DSP
Page 20: ...www trilithic com 180 DSP Signal Level Meter Section I The Basics ...
Page 66: ...www trilithic com 180 DSP Signal Level Meter Section II Setup Menu ...
Page 175: ...www trilithic com 180 DSP Signal Level Meter Section III Autotest Menu ...
Page 197: ...www trilithic com 180 DSP Signal Level Meter Section IV Troubleshoot Menu ...
Page 361: ...www trilithic com 180 DSP Signal Level Meter Section V Utility Menu ...
Page 375: ...www trilithic com 180 DSP Signal Level Meter Section VI Appendix ...
Page 386: ...9710 Park Davis Drive Indianapolis IN 46235 317 895 3600 www trilithic com Made in U S A ...