Ethernet communicator E10Tv2
3.3
Reporting → Protegus service
Protegus service allows users to remotely monitor and control the communicator.
Protegus service allows simultaneous transmission of data to the Protegus server for Mobile/Web application.
For more information about PROTEGUS service visit
Enable cloud service at Reporting → PROTEGUS service tab.
Enter Service code (default code – 123456), for more safety change it to 6-symbol authentication code.
This code is used, when adding new system to the application and controlling remotely via TrikdisConfig
software (for more details refer to
5. TrikdisConfig remote control
3.4
Event Summary
Input description
•
Describe input by filling in fields (these will be sent if Alarm/Restore occurs):
o
Partition;
o
Contact ID - can be customized or left default value;
o
Zone No - describe which zone will be controlled with IN 1;
•
Select Type of input (NO, NC, EOL);
•
Enable: report when event occurs (Alarm); report when input line will restore (Restore).
Internal events description
•
To describe internal events select event type (Event or Restore), Contact ID code can be changed, enter
Partitions and Zone.