2
I56-5846TRG-003
2/1/2021
FIGURE 3. LIGHT OUTPUT - VERTICAL DISPERSION, CEILING TO WALLS
TO FLOOR
Degrees*
Percent of
Rating
0
100
5-25
90
30-45
75
50
55
60
45
65
35
70
35
75
30
80
30
85
25
90
25
FIGURE 4. LIGHT OUTPUT –
FIGURE 5. VERTICAL
HORIZONTAL DISPERSION
DISPERSION, WALL TO FLOOR
Degrees*
Percent of Rating
Degrees*
Percent of Rating
0
100
0
100
5-25
90
5-30
90
30-45
75
35
65
50
55
40
46
55
45
45
34
60
40
50
27
65
35
55
22
70
35
60
18
75
30
65
16
80
30
70
15
85
25
75
13
90
25
80
12
Compound 45
to the left
24
85
12
Compound 45
to the right
24
90
12
A0467-00
A0469-00
*Tolerance of ±1 degree is permitted.
This is generated text for figtxt.
FIGURE 1. AUDIO SELECTOR
A0518.00
FIGURE 2. CANDELA SELECTOR
A0486-00
TABLE 1. HORN TONES
TABLE 2. CHIME TONES
Pos
Tone
Volume
Setting
Pos
Tone
Volume
Setting
1
Temporal
High
1
1 Second Chime
High
2
Temporal
Low
2
1 Second Chime
Low
3
Non-Temporal
High
3
¼ Second Chime
High
4
Non-Temporal
Low
4
¼ Second Chime
Low
5
3.1 KHz
Temporal
High
5
Temporal Chime
High
6
3.1 KHz
Temporal
Low
6
Temporal Chime
Low
7
3.1 KHz
Non-Temporal
High
7
5 Second Whoop
High
8
3.1 KHz
Non-Temporal
Low
8
5 Second Whoop
Low
TABLE 3. CEILING-MOUNT STROBE CURRENT DRAW (mA)
Candela
8-17.5
Volts
16-33 Volts
DC
DC
FWR
15
87
41
60
NOTE:
Products set at 15 and 30
candela automatically work on
either 12V or 24V power supplies.
The products are not listed for
12V DC operation when set to any
other candela settings.
30
153
63
86
75
-
111
142
95
-
134
164
115
-
158
191
150
-
189
228
177
-
226
264
CURRENT DRAW AND AUDIBILITY RATINGS
For the horn strobe, the current draw and audibility ratings for each setting is
listed in Table 4. For the chime strobe, the current draw and audibility ratings
for each setting is listed in Table 5. For the strobe, the current draw for each
setting is listed in Table 3.
TABLE 4. CEILING--MOUNT HORN STROBE CURRENT DRAW (mA) AND SOUND OUTPUT (dBA)
Current draw (mA)
Sound Output (dBA)
Pos
Tone
Volume
Setting
8-17.5 VDC
16-33 VDC
16-33 FWR
8-17.5 V 16-33 V
15
30
15
30
75
95
115 150 177
15
30
75
95
115 150 177
DC
DC FWR
1
Temporal
High
103
167
71
90
143
165
187
217
254
107
135
179
198
223
254
286
84
89
89
2
Temporal
Low
96
165
54
71
137
161
185
211
249
78
101
151
172
199
229
262
75
83
83
3
Non-Temporal
High
106
173
71
90
141
165
187
230
273
107
135
179
198
223
254
286
85
90
90
4
Non-Temporal
Low
95
166
54
71
124
161
170
216
258
78
101
151
172
199
229
262
76
84
84
5
3.1 KHz
Temporal
High
111
164
69
94
147
163
184
229
257
108
135
179
200
225
255
289
83
88
88
6
3.1 KHz
Temporal
Low
103
163
54
88
143
155
185
212
252
79
101
150
171
196
229
260
76
82
82
7
3.1 KHz
Non-Temporal
High
111
172
69
94
144
164
202
229
271
108
135
179
200
225
255
289
84
89
89
8
3.1 KHz Non-
Temporal
Low
103
169
54
88
131
155
187
217
259
79
101
150
171
196
229
260
77
83
83
NOTE:
Products set at 15 and 30 candela automatically work on either 12V or 24V power supplies. The products are not listed for 12VDC operation when set to
any other candela settings.
A0468-00