World Class Components
Installation & Operation Guide
FOAMATE
Model 1.0 ATP System
Revised 12/28/2016
Page 1 of 2
(
215-293-0700
7
215-293-0701
Trident Emergency Products, LLC
2940 Turnpike Drive | Suite #9 | Hatboro, Pennsylvania 19040 USA
MOUNT UNIT:
Foamate 1.0 unit may be panel mounted or bracket mounted.
▶
For panel mount; remove knob, faceplate, wheel and faceplate carrier to
remove brass washer as noted above. Match-mark the wheel holes for
reassembly. After cutting hole in panel as shown in diagram, insert the
Foamate body from behind the panel, with the panel replacing the brass
washer (panel thickness must be
1
⁄
8
") and reassemble components outside the
panel in reverse order as disassembled above.
▶
For bracket mount use the (4)
1
⁄
4
"-20 tapped holes on the back of the Foamate
body to connect a simple bracket that locates the unit in a convenient
location, using diagram shown.
PLUMB UNIT:
The Foamate 1.0 is supplied with (2)
3
⁄
4
" F NPT strainers.
▶
Tee a line of at least
1
⁄
4
" ID from the discharge of the pump to the water
strainer and from the strainer to “water-in” connection on the Foamate as
shown. Note a
1
⁄
2
" ball valve can be plumbed to the strainer for easy flushing.
▶
Connect another line at least
3
⁄
8
" ID from the “solution-out” back to the pump
suction as shown. If the line length exceeds 5', use
1
⁄
2
" ID line to reduce back
pressure.
▶
Finally, connect a line at least
3
⁄
4
" ID from the foam source to the foam strainer,
and from the strainer to the “foam-in”
3
⁄
4
" GHT connection on the back of the
Foamate.
OPERATE UNIT:
The Foamate 1.0 is designed to be very user friendly, and the
operating instructions are printed right on the control head.
▶
Start by selecting the Class A Foam percentage desired, 0.25, 0.50, or 1.0%.
This is accomplished by rotating the black rimmed window in the upper left
corner until the arrow head (just to the left of the CIRCULAR window) points
to the desired foam percentage.
▶
Then rotate the outer wheel to match the total nozzle Flow GPM. This will
match the nozzle flow rating at 100 PSIG [6.9 BAR]. The flow GPM is read
inside the circular window on the upper left corner Foam percent selector
mentioned above.
▶
Run the pump up to a discharge pressure of 100 PSIG [6.9 BAR], this will
provide for optimum foam proportioning accuracy.
▶
Open the center knob by turning to the right (clockwise) to ON to begin foam
injection.
▶
When foam is not desired, turn the center knob to the left (counter-clockwise)
to OFF. This will also allow for constant flushing.
▶
Clean water and foam Wye-strainers as required. This is done by removing
the
1
⁄
2
" NPT plug and cleaning-out strainer element, or by opening the
1
⁄
2
"
valve (if provided) on the water strainer.
3
⁄
4
" MGHT
Foam In
3
⁄
8
" FNPT
Solution Out
1
⁄
4
" FNPT
Water In
4.26
4.00
1.00
1.75
2.00
1.375
1.375
1.188
HEX
(4)
1
⁄
4
- 20 UNC
↧
.500
2.53
Remove Brass Washer
for Panel Mounting
CLASS A
FOAM TANK
Water Pump
Trident
Supplied
Items
Two Cleanable Wye
strainers included:
▶
One for Water
▶
One for Foam
Valve may be added to
strainer cleanout for flushing.
100
PSI
Foam Solution
to Discharge
Outlets.
PANEL or BRACKET CUTOUT DIAGRAM