Trident Foamate 1.0 Installation & Operation Manual Download Page 1

World Class Components

Installation & Operation Guide

FOAMATE

 

Model 1.0 ATP System

Revised 12/28/2016

Page 1 of 2

215-293-0700 

7

 

215-293-0701

[email protected]

Trident Emergency Products, LLC
2940 Turnpike Drive | Suite #9 | Hatboro, Pennsylvania 19040 USA

MOUNT UNIT:

Foamate 1.0 unit may be panel mounted or bracket mounted.

 

For panel mount; remove knob, faceplate, wheel and faceplate carrier to 
remove brass washer as noted above. Match-mark the wheel holes for 
reassembly. After cutting hole in panel as shown in diagram, insert the 
Foamate body from behind the panel, with the panel replacing the brass 
washer (panel thickness must be 

1

8

") and reassemble components outside the 

panel in reverse order as disassembled above.

 

For bracket mount use the (4) 

1

4

"-20 tapped holes on the back of the Foamate 

body to connect a simple bracket that locates the unit in a convenient 
location, using diagram shown.

PLUMB UNIT:

The Foamate 1.0 is supplied with (2) 

3

4

" F NPT strainers.

 

Tee a line of at least 

1

4

" ID from the discharge of the pump to the water 

strainer and from the strainer to “water-in” connection on the Foamate as 
shown. Note a 

1

2

" ball valve can be plumbed to the strainer for easy flushing.

 

Connect another line at least 

3

8

" ID from the “solution-out” back to the pump 

suction as shown. If the line length exceeds 5', use 

1

2

" ID line to reduce back 

pressure.

 

Finally, connect a line at least 

3

4

" ID from the foam source to the foam strainer, 

and from the strainer to the “foam-in” 

3

4

" GHT connection on the back of the 

Foamate.

OPERATE UNIT:

The Foamate 1.0 is designed to be very user friendly, and the 
operating instructions are printed right on the control head.

 

Start by selecting the Class A Foam percentage desired, 0.25, 0.50, or 1.0%. 
This is accomplished by rotating the black rimmed window in the upper left 
corner until the arrow head (just to the left of the CIRCULAR window) points 
to the desired foam percentage.

 

Then rotate the outer wheel to match the total nozzle Flow GPM. This will 
match the nozzle flow rating at 100 PSIG [6.9 BAR]. The flow GPM is read 
inside the circular window on the upper left corner Foam percent selector 
mentioned above.

 

Run the pump up to a discharge pressure of 100 PSIG [6.9 BAR], this will 
provide for optimum foam proportioning accuracy.

 

Open the center knob by turning to the right (clockwise) to ON to begin foam 
injection.

 

When foam is not desired, turn the center knob to the left (counter-clockwise) 
to OFF. This will also allow for constant flushing.

 

Clean water and foam Wye-strainers as required. This is done by removing 
the 

1

2

" NPT plug and cleaning-out strainer element, or by opening the 

1

2

valve (if provided) on the water strainer.

3

4

" MGHT

 

Foam In

3

8

" FNPT

 

Solution Out

1

4

" FNPT

 

Water In

4.26

4.00

1.00

1.75

2.00

1.375

1.375

1.188

HEX

(4) 

1

4

 - 20 UNC 

 .500

2.53

Remove Brass Washer 
for Panel Mounting

CLASS A

FOAM TANK

Water Pump

Trident 
Supplied 
Items

Two Cleanable Wye 
strainers included:

 

One for Water

 

One for Foam

Valve may be added to 

strainer cleanout for flushing.

100

PSI

Foam Solution 

to Discharge 

Outlets.

PANEL or BRACKET CUTOUT DIAGRAM

Reviews: