Spectrum Essential Oil Storage System
TRICO CORPORATION
1235 Hickory Street; Pewaukee, WI 53072
For Customer Support: 800-558-7008
P a g e
15 | 20
MAINTENANCE CHECKLIST
Trico Spectrum Oil Storage Systems should have scheduled, routine maintenance every three months
after installation. Personal Protective Equipment (“PPE”) should be worn when performing any
maintenance service on the system.
CAUTION:
The Tank Shut-Off valves, located under the tank, must be in the closed
position when servicing the system. Main power supply should be removed and
locked out before any service is performed.
Check and replace Watchdog Extreme Humidity Desiccant Breathers. The orange beads will turn
dark green indicating the desiccant has been used.
Inspect all hoses for crack or kinks
Inspect all fitting for leaks
Inspect and tighten all bolts as needed
Clean all surfaces and motor
Empty Spill Containment pan either by the 1” NPT hole on bottom of pan, or by using the
suction wand and discharge valve into a separate container
MOVING THE SYSTEM
Trico Spectrum Oil Storage Systems can be easily moved around with a hand pallet truck, or forklift.
Follow the procedures below to relocate the system.
1.
Empty all Tanks and hoses.
2.
Close Tank Shut-Off Valves on the bottom of the Tanks.
3.
Close all valves on the Tank Manifold on the Pump Stack.
4.
Remove any additional Storage Stack hoses from the Tank Manifold.
5.
Disconnect the power by removing the electrical plug at the outlet or turn the power off at the
breaker to each motor.
6.
Empty and clean out Spill Containment.
7.
Remove bolts from surface mounting holes, if mounted.
8.
Move System into new location using a hand pallet truck or forklift. There should be a minimum
of 12” of space from the back of the Spill Containment. This provides room for the hoses. More
room may be required behind the units for maintenance and easier access to the tank shut-off
valves, up to 24”.
9.
Once in place, continue with normal installation steps.