10
Testing in accordance with EN 60704 must be carried out with appliance fully loaded and using the test programme (see "Washing
programmes" chart).
Test in accordance with EN 50242 must be carried out when the salt dispenser and rinse aid container have been filled with salt and
rinse aid respectively and using the test programme (see "Washing programmes" chart).
Hints for test centres
Load:
12 standard place settings
Rinse aid setting
Rinse aid dispenser (type A):
position 4 (type III)
Rinse aid dispenser (type B):
position 5 (type III)
Detergent dosage:
5 g + 25 g (type B)
Arrangement upper basket
Arrangement lower basket
Arrangement cutlery basket