14
4.2
Lifting tanks of 5-6 modules (Max. 6.6m)
•
Tanks which are greater than four modules (4.6m) in length should be lifted using the slings
provided as depicted per
Option 3
, shown below. However, on sites where lifting height is
restricted, a lifting bar should be used as shown in
Option 4
:
Note: To ensure the angle of the sling is not greater than 60
o
, as per
Option 1
above, the following
sling lengths are required:
Length of tank
Minimum length of sling
2.1
2.1
2.6
2.6
3.1
3.1
3.6
3.6
4.6
4.6
5.6
5.6
6.6
6.6