background image

OPTICAL POWER METER

USER'S GUIDE

Summary of Contents for EPM30

Page 1: ...OPTICAL POWER METER USER S GUIDE...

Page 2: ...ble the cabinet Avoiding condensation problems As much as possible avoid sudden temperature changes Do not attempt to use the drive immediately after moving it from a cold to a warm location to raisin...

Page 3: ...accessories If any accessory isshort please relate withthe dealer ASAP Standard REF Save 2S PERM Optical Communication Instrument Unit Host OPTICAL POWER METER USER S GUIDE Manual Optional Chargeing...

Page 4: ...3 1 2 6 3 7 8 9V 1A 9V 1A 9 10 11 4 5 4 Wavelength shift key 7 Unit shift key dBm uW 8 Reference key 1 Fiber Adaptor 2 LCD 3 Power key 10 Battery charge jack 11 Led for battery charge 9 USB power sup...

Page 5: ...4 1 Press and push down 2 Open the lid 3 Place the batteries 4 Close the lid and push up Set batteries Warning At the sametime can not usedifferent style and different capacitance batteries...

Page 6: ...Power key to turn on the device with auto power off After 10 minutes no key pressed it will auto power off Press Power key for 2 seconds when turn on the device the auto power off will be cancelled a...

Page 7: ...M Optical Communication Instrument Unit PERM 2KHz REF nm dBm When testing you must select the right wavelength Press the key for shifting the wavelength from 850nm 1300nm 1310nm 1490nm 1550nm 1625nm W...

Page 8: ...F Save 2S PERM Optical Communication Instrument Unit PERM 2KHz REF nm dBm Unit Unit select Press the key for shifting the unit from dBm mW uW dB mW uW 1mW 1000uW 1uW 1000nW dBm dBm 10 log mW dB dB dBm...

Page 9: ...z REF nm dBm REF Reference Press key to check the reference value you set last time And if keep pressing for 2 seconds you can store the current dBm as a new reference value Then it automatically shif...

Page 10: ...ent Unit PERM 2KHz REF nm dBm 9 88 Record 88 Record Data Storage and backlight When in testing interface user can press key And press the key for 2 seconds to the History interface to save current val...

Page 11: ...ERM Optical Communication Instrument Unit PERM 2KHz REF nm dBm Battery energy detect Remain80 100 If the energy is too low the beep will be on and device will auto power off Remain40 80 Remain20 40 Re...

Page 12: ...ication on LCD will flash After charging fully the indication will stop flashing and show full Don t charge for more than 24 hours If charging while using the device the time will be longer The rechar...

Page 13: ...eries Common malfunction Described Described Can not turn on After turn on shut it immediately Malfunction cause Malfunction cause Display the messy code Reset is incorrect Operation do not have react...

Page 14: ...dB 50 60dBm 0 1dB 26 40dBm 0 01dB 40 50dBm 0 1dB Wave respond Calibrated wavelengths Display resolving power Connector adapter Measuring range Auto off Yes Size AA Alkaline cell or NiMH cell FC or SC...