6.3.2 Actions with the activation and programming key
The activation and programming key attached to the housing of the FP4 B allows you to
perform actions and changes in the settings of the FP4 B. This activation and program-
ming key can be easily and permanently stored on the FP4 B.
1. Remove the activation and programming
key.
Turn the activation and programming key
to the OPEN position and remove it from the
housing of the FP4 B.
The activation and programming key
is stored in the opening on the top of the
housing of the FP4 B. It is also used to seal
the FP4 B.
2. Guide the activation and programming
key to the action area.
Place the activation and programming key
on the action area on the front of the FP4 B.
Ü
As soon as the activation and program-
ming key on the action area has been
detected by FP4 B, the yellow LED in the
LCD lights up. The menu runs in a rhythm of
approx. 2 seconds.
Remove the activation and programming
key from the action area as long as the desi-
red menu item is displayed in the LCD.
Ü
The yellow LED disappears. You have
performed an action. The LCD flashes
together with the green LED twice.