FlexxPump1 B
User Manual
18
EN-
6.
Operation and settings
6.1
General information
What you should know about operating and setting the FP1 B:
FP1 B is designed as a single point lubricator for one lubrication point. However, de-
pending on the specific application, FP1 B can also supply a limited number of lubricati-
on points reliably and cleanly with lubricant. Accessories from the manufacturer can be
connected to the FP1 B. If necessary, changes must be made to the FP1 B settings to
ensure safe and reliable operation.
The FP1 B is a cycle-controlled lubricant dispenser which operates autonomously and
time-based via the integrated microelectronics. The FP1 B cyclically delivers a defined
quantity of lubricant from the cartridge to the outlet. Two operating modes can be
selected. The
Hour-Mode -h-
allows setting the number of cycles (c) within a dispen-
sing time (h) in hours. The cycles (c) are evenly distributed over the dispensing time.
Dispensing times (h) between 1...99 hour(s) and cycles (c) between 1...10 can be set.
The
Empty-Time-Mode Et
allows the emptying time of the cartridge to be set in
months. Emptying times between 1...24 month(s) can be set.
The disposable interchangeable cartridge with 125ml lubricant guarantees a control-
led and constant quality of the lubricant and is filled without air bubble inclusions. The
FP1 B allows a high supply security of the lubrication point and prevents failures. The
FP1 B in its present version is designed for the lubricant grease and oil.
The FP1 B cannot be used in the present version without a lubricant cartridge and
suitable battery. Both can - depending on the version ordered - already be included in
the scope of delivery and may already be connected and installed in the FP1 B.
For operation under normal operating conditions, FP1 B can be operated with an
alkaline battery, for increased requirements with the more powerful lithium battery.
The respective conditiones of the FP1 B can be seen in the LCD, which additionally
enables the optical recognition of the condition by means of coloured LEDs.
If you have any questions about your application and the correct settings for FP1 B,
please contact the manufacturer (chapter I.II).