Programmable Multiband Amplifier
TMB 200 & TMB 200S
16
awi -july 14
TMB 200-V1
AGC
AGC
AGC
ON
AGC
OFF
Error code
Auto
117
Auto Level
117
AUTO lvl
Wait
p
p
Menu
p
p
Menu
p
p
Menu
Menu
+
-
+
-
Unit in standby mode, push a button to reach the
SETTINGS
/
Config
menu.
Press the
button until
the display shows the
AGC
menu.
Press
Menu
button to enter the function
Press the buttons
+
or
-
to select
on
or
off
Confirm by pressing
Menu
IMPORTANT!
AGC: The unit memorizes the average output level. A variation of ± 1 dB triggers the function
and compensates the variation within gain and attenuation limits
AGC mode hides all other menus. To modify the parameters, switch the AGC mode to OFF
.
Auto level
Unit in standby mode, push a button to reach the
SETTINGS
/
Config
menu.
Press the
button until
the display shows the
Auto
menu.
Press
Menu
button to enter the function
Press the buttons
+
or
-
to select the output level value
Confirm by pressing
Menu
IMPORTANT!
The unit memorizes the selected output level, the function try to reach the value within input,
gain and attenuation limits.
Note:
Setting of VHF level is not automatic.