- 7 -
CGSD 162
5
C
onneCting
the
sat if
input
distributor
5.1 C
onneCting
the
hf
ConneCtions
• Connect the outputs
E
and
F
(page 5) to the appropriate inputs of the
modules.
u
sing
one
reCeption
area
(
loop
-
through
mode
)
• Connect input
D
of the SAT IF input distributor to one of the pre-installed
F terminals
4
in the rear wall of the head-end station using a HF cable
made on-site (length approx. 30 cm).
• Connect the loop-through output
C
to input
B
using a HF cable made on-
site (length approx. 30 cm).
4
D
C
B
u
sing
t wo
reCeption
areas
• Connect inputs
B
and
D
of the SAT IF input distributor to the appropriate
pre-installed F terminals
4
in the rear wall of the head-end station using HF
cables made on-site (length approx. 30 cm).
• Terminate the loop-through output
C
with the terminator supplied.
4
D
C
B