- 12 -
CGS-2 764 C
4
t
he
Control
panel
at
a
glanCe
4.1 f
unCtions
of
the
Control
panel
but tons
S
M
To move the cursor
To adjust values and
functions
To save the programmed
data
To switch to the next
menu
4.2 m
enu
items
Program the QAM module using the buttons on the head-end station control
panel. The menus appear on the two-line display of the control panel.
The parameters and functions to be set are underlined.
With the button select the channel strip / other modules.
You can use the button to select the following menu items:
– Output signal settings:
Modulator on/off, level
Output channel (modulators A and C)
Output frequency (modulators A…D)
QAM modulation
Substitute signal
– Input signal settings:
LNB oscillator frequency
Input symbol rate
Input frequency
Station filter
CA module
Economize descrambling capacity
– Options:
Transport stream and ORGNET-ID
BAT, STD-other
Deleting a PID
Renaming a PID
– Data rate
– Network Information Table (NIT)
– Factory reset
– Save data