USB Mini Spectrum Analyzer User Manual

 

PC program TSA

For TS

A4G1

TSA

6

G1

TSA

8

G1

TSA12G5

Triarchy Technologies, Corp.

Page 

1

 of 

17

Summary of Contents for TSA12G5

Page 1: ...67 15233 34th Ave Surrey BC V3S 2T7 604 637 2167 info triarchytech com USB Mini Spectrum Analyzer User Manual PC program TSA For TSA4G1 TSA6G1 TSA8G1 TSA12G5 Triarchy Technologies Corp Page 1 of 17 ...

Page 2: ...blication may be reproduced transmitted transcribed stored in a retrieval system or translated into any language or computer language in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without the prior written permission of Triarchy Technologies Corp Technical Support For technical support please call 1 604 637 2167 send email to info triachytech com o...

Page 3: ... 4 AMPLITUDE SETTING 11 2 5 SWEEP TIME SETTING 11 2 6 TRACE SELECTION 11 2 7 CURRENT TRACE 12 2 8 AVERAGE TRACE 12 2 9 MAX TRACE 12 2 10 DENSITY MEASUREMENT 13 2 11 MANUAL CALIBRATION 13 3 MEASUREMENT SUPPORT FEATURES 13 3 1 SELECT MEASUREMENT CURVE 13 3 2 MARKER 13 3 3 DELTA MARKER 14 3 4 CHANNEL POWER 14 3 5 LIMIT LINE 15 3 6 REFERENCE 15 3 7 HARDCOPY 15 3 8 RECORDING 15 3 9 DISPLAY MOVING 15 4 ...

Page 4: ... Windows Vista and Window 8 1 Gigahertz GHz or faster 32 bit x86 or 64 bit x64 processor 1 Gigabyte GB RAM 32 bit or 2 GB RAM 64 bit 100 MB hard disk space Buffered data may need extra space Display resolution shall be better than 1024x768 Insert CD into the computer open the SW_ file TSA folder from CD and click the setup exe to install software When you see the installation window click Next Ple...

Page 5: ...nstalled you will get the message Finish the Installation Completely please see Figure 2 TSA program will install at C Program Files x86 Triarchy Tech TSA Spectrum Analyzer TSA data folder will be located at Documents all the log data and Calibration file will put into data folder the data folder path is C Users UserName Documents Triarchy Tech TSA Spectrum Analyzer Please see Figure 4 Page 5 of 1...

Page 6: ...dat file file was demo version the calibration file in your CD will be related to your ordered device You must copy it to replace the demo Demo version Please request these 2 files from support triarchytech com if you do not have a CD If your product is TSA5G35 you need to remove the amp_ofst dat then copy calibration file lic dat and freq_ofst dat which in your CD into the installed folder freq_o...

Page 7: ... t find calibration file warning appears Figure 6 It means the amp_ofst dat and freq_ofst dat file from CD is missing in the data folder Figure 6 Needs to copy Calibration file If the If the installation was successful you will see spectrum analyzer application start up window as shown in Figure 7 Figure 7 Application Windows before USB Device Connected Page 7 of 17 ...

Page 8: ...ice S N If PC connects to USB device properly the USB Message is shown Device Connected Please see Figure 7 Figure 7 TSA Connected with USB Mini Spectrum Analyzer Device 1 2 Uninstall PC Application If you want to uninstall the TSA program please go to the Start menu look for the Triarchy Tech folder then click Uninstall item and follow the instruction Please see Figure 8 Figure 8 Uninstall View P...

Page 9: ...s 0 dBm and the center frequency is 1000MHz When a signal presents at the input the signal spectrum will be displayed In this example the signal center is at 1000 MHz The spectrum display by default shows only the current trace The average trace peak trace and density of the signal level are turned off If you want to turn on different traces you can enable different traces by clicking tabs to disp...

Reviews: