background image

Page 5

IR104-V4 User Guide

Rev A

Input Change Flags (ICF) ................................................................................................................14

ICF Grouping ........................................................................................................................................... 14
ICF I/O Map.............................................................................................................................................. 14

Interrupts Control Register (ICR) .....................................................................................................15

ICR Grouping ........................................................................................................................................... 15
ICR I/O Map ............................................................................................................................................. 15

Base Addresses .....................................................................................................................................16

Warranty and Product Information ..........................................................................................................17

Tri-M Technologies Inc. (Limited Warranty) .....................................................................................17
Disclaimer ........................................................................................................................................17

Appendix ....................................................................................................................................................18

Frequently Asked Questions (FAQ) .......................................................................................................18

Contents

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for IR104-20

Page 1: ...underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of their respective o...

Page 2: ...ee 1 800 665 5600 Direct 1 604 945 9565 Email info tri m com Web www tri m com IR104 V4 User Guide Opto isolated Industrial I O Relay Module Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 3: ... user should be familiar with practicing safe techniques while making supply or pin connections User Guide Revision History Revision Date Description A 12 Jan 2012 Rebranded Trademarks Trademarks registered trademarks and product names are the property of their respective owners and are used herein for identification purposes only Contact Information Tri M Technologies Inc 101 1530 Kingsway Avenue...

Page 4: ...uching the board may result in electrical shock even if the board has not been switched on yet Electrostatic Discharge ESD Precautions To avoid electrostatic discharge or transient voltage damage to the board observe the following procedures Before touching the board discharge your body and any tools you use from electricity Ensure that the board or the unit you want to install the board on is de ...

Page 5: ...nvironmental Specifications 7 Mechanical Specifications 7 MTBF 7 Certifications 7 Dimensions and Connector Locations 8 2 Connectors 9 Connector Overview 9 Terminal Plugs CN1 CN2 9 Opto isolated Inputs CN4 10 PC 104 8 bit Bus J1 11 PC 104 16 bit Bus J2 12 3 Configuration 13 I O Map 13 Relay Output Control ROC 13 ROC Grouping 13 ROC I O Map 13 Digital Input Reading DIR 13 DIR Grouping 13 DIR I O Map...

Page 6: ...ol Register ICR 15 ICR Grouping 15 ICR I O Map 15 Base Addresses 16 Warranty and Product Information 17 Tri M Technologies Inc Limited Warranty 17 Disclaimer 17 Appendix 18 Frequently Asked Questions FAQ 18 Contents Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 7: ...t proservices html Key Specifications 20 Opto isolated bi directional inputs with 3000V protection 20 SPST Output Relays with 20 000 000 Lifetime Cycles Input Voltages from 3V to 24V AC or DC and Output UL ratings of 5A 30 VDC and 250VAC I O Map configuration options such as Relay Output Control Digital Input Reading Input Change Flags and Interrupt Control Registers Operating Temperature 25 C to ...

Page 8: ...ions Operating Temperature 25 C to 70 C 13 F to 158 F Mechanical Specifications Input Relays 20 Opto isolated Inputs Output Relays 20 SPST Output Relays Relay Lifetime 20 000 000 min 70 000 min at rated loads Dimensions PC 104 Compliant 90 96mm 3 55 3 78 Component Height 12 49mm 0 492 slightly over the 0 435 PC 104 standard Weight 127 12 g 4 48 oz MTBF 57 098 hours 30 C 86 F Ambient Temperature Ce...

Page 9: ...inal block Wieland 25 640 0553 0 CN2 9 10 Output Relays for 14 24 AWG wire 20 pin socket Wieland 25 647 0553 0 mates with screw terminal block Wieland 25 640 0553 0 CN4 10 20 Opto isolated Inputs 2 20 position pin header JP1 16 Jumper Block for Address Selection 3 1 jumper block JP2 16 Jumper Block for Address Selection 3 1 jumper block J1 11 PC 104 8 bit ISA PC 104 Connector 2 32 press fit header...

Page 10: ...ock plugs intended for 14 24 AWG wires They have a UL certified contact rating of 5A 30VDC and 250VAC Relay 20 Relay 19 Relay 18 Relay 17 Relay 16 Relay 15 Relay 14 Relay 13 Relay 12 Relay 11 Relay 1 Relay 2 Relay 3 Relay 4 Relay 5 Relay 6 Relay 7 Relay 8 Relay 9 Relay 10 SPST relay contact example Note The terminal sockets are Wieland 25 647 0553 0 which mate with the screw terminal block plugs W...

Page 11: ...r AC For higher input voltage requirements please contact our Professional Services Team see Contact Information on page 2 or visit http www tri m com support proservices html PCB TOPVIEW 1 39 CN4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 3V to 24V DC or AC input 2 Connectors 2 COM Ω Ω Pull up in PLD 0 1µF 5V 4 99 k 4 99 k Input Connector Input Optocoupler 40 Artisan Technology Group Qual...

Page 12: ...REFRESH A4 SD5 B4 IRQ9 A20 SA11 B20 SYSCLK A5 SD4 B5 5V A21 SA10 B21 IRQ7 A6 SD3 B6 DRQ2 A22 SA9 B22 N A A7 SD2 B7 12V A23 SA8 B23 IRQ5 A8 SD1 B8 0WS A24 SA7 B24 IRQ4 A9 SD0 B9 12V A25 SA6 B25 IRQ3 A10 IOCHRDY B10 GND A26 SA5 B26 DACK2 A11 AEN B11 SMEMW A27 SA4 B27 TC A12 SA19 B12 SMEMR A28 SA3 B28 BALE A13 SA18 B13 IOW A29 SA2 B29 5V A14 SA17 B14 IOR A30 SA1 B30 OSC A15 SA16 B15 DACK3 A31 SA0 B31...

Page 13: ...1 SBHE D1 MEMCS16 C2 LA23 D2 IOCS16 C3 LA22 D3 IRQ10 C4 LA21 D4 IRQ11 C5 LA20 D5 IRQ12 C6 LA19 D6 IRQ15 C7 LA18 D7 IRQ14 C8 LA17 D8 DACK0 C9 MEMR D9 DRQ0 C10 MEMW D10 DACK5 C11 SD8 D11 DRQ5 C12 SD9 D12 DACK6 C13 SD10 D13 DRQ6 C14 SD11 D14 DACK7 C15 SD12 D15 DRQ7 C16 SD13 D16 5V C17 SD14 D17 MASTER C18 SD15 D18 GND C19 GND D19 GND 2 Connectors C0 C19 D19 DO TOPSIDE J2 Artisan Technology Group Quali...

Page 14: ... Relay 11 Relay 10 Relay 9 ROC Bank 3 Not used Not used Not used Not used Relay 20 Relay 19 Relay 18 Relay 17 ROC I O Map Digital Input Reading DIR The DIR bank is accessed through I O reads and are grouped in two banks of eight and one bank of four A logic 0 read for an input indicates the corresponding physical input is powered A logic 1 read on any input indicates the corresponding physical inp...

Page 15: ... O Map Note An input change flag can be cleared by reading the corresponding input bank 3 Configuration ICF Grouping Bank Flags Address ICF Bank 1 F1 to F8 I O address Base Address 8 0 08 ICF Bank 2 F9 to F16 I O address Base Address 9 0 09 ICF Bank 3 F17 to F20 I O address Base Address 10 0 0A Note The I O address is an offset from the base decoded address Bank SD7 SD6 SD5 SD4 SD3 SD2 SD1 SD0 DIR...

Page 16: ...4 IE3 IE2 IE1 ICR Bank 2 IE16 IE15 IE14 IE13 IE12 IE11 IE10 IE9 ICR Bank 3 IRQen7 IRQen6 IRQen5 IRQen4 IE20 IE19 IE18 IE17 ICR Grouping Bank Interrupts Address ICR Bank 1 IE1 to IE8 I O address Base Address 12 0x0C ICR Bank 2 IE9 to IE16 I O address Base Address 13 0x0D ICR Bank 3 IE17 to IE20 IRQen4 to 7 I O address Base Address 14 0x0E ICR I O Map Note An Interrupt will stay asserted until all t...

Page 17: ...puts 17 to 20 ICF Bank 1 0x248 0x268 0x288 0x308 Change Flag Inputs 1 to 8 ICF Bank 2 0x249 0x269 0x289 0x309 Change Flag Inputs 9 to 16 ICF Bank 3 0x24A 0x26A 0x28A 0x30A Change Flag Inputs 17 to 20 ICR Bank 1 0x24C 0x26C 0x28C 0x30C Interrupt Enables Inputs 1 to 8 ICR Bank 2 0x24D 0x24D 0x28D 0x30D Interrupt Enables Inputs 9 to 16 ICR Bank 3 0x24E 0x26E 0x28E 0x30E Interrupt Enables Inputs 17 to...

Page 18: ...er this warranty or the failure or incorrect use of any of its products This warranty is in lieu of all warranties either express or implied including without limitation any implied warranty of merchantability or fitness for any particular purpose and of any other obligation on the part of Tri M Disclaimer No part of this document may be reproduced transmitted transcribed stored in a retrieval sys...

Page 19: ...clude input change flags interrupt enables and software IRQ selection Is the IR104 V4 software compatible with other IR104 version IR104 software support is compatible with previous versions All new features have been set in previously unused I O registers Is the IR104 RoHS Compliant All Tri M s products are RoHs and we also provide other customizable options depending on your requirements What is...

Page 20: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...

Reviews: