Server Port
Recipients
server UDP port number, if “use default”
checked the value is 162, else user configure.
Timeout
Specify th
e SNMP informs timeout, if “use default”
checked the value is 15, else user configure.
Retry
Specify the SNMP informs retry count, if
“use default”
checked the value is 3, else user configure.
Log Server
This section will allow users to configure an external remote log server or syslog server.
After you have completed configuration, click
Add, Apply
, and click
Save.
Item
Description
Server
Address
The IP address of the remote logging server.
Server
Ports
The port number of the remote logging server.
Facility
The facility of the logging messages. It can be one of the
following values: local0,local1, local2, local3, local4, local5,
local6, and local7.
Severity
The minimum severity.
•
Emergence: System is not usable.
•
Alert: Immediate action is needed.
•
Critical: System is in the critical condition.
•
Error: System is in error condition
•
Warning: System warning has occurred
•
Notice: System is functioning properly, but a system notice
has occurred.
•
Informational: Device information.
•
Debug: Provides detailed information about an event.