© Copyright 2019 TRENDnet. All Rights Reserved.
TRENDnet User’s Guide
TL2-FG142
31
Items
Description
Delete
Check to delete the entry. It will be deleted during the next save.
ID
Indicates the index of the entry. The range is from 1 to 65535.
Interval
Indicates the interval in seconds for sampling and comparing the rising
and falling threshold. The range is from 1 to 2^31-1.
Variable
Indicates the particular variable to be sampled, the possible variables are:
InOctets: The total number of octets received on the interface, including
framing characters.
InUcastPkts: The number of uni-cast packets delivered to a higher-layer
protocol.
InNUcastPkts: The number of broad-cast and multi-cast packets delivered
to a higher-layer protocol.
InDiscards: The number of inbound packets that are discarded even the
packets are normal.
InErrors: The number of inbound packets that contained errors preventing
them from being deliverable to a higher-layer protocol.
InUnknownProtos: the number of the inbound packets that were
discarded because of the unknown or un-support protocol.
OutOctets: The number of octets transmitted out of the interface ,
including framing characters.
OutUcastPkts: The number of uni-cast packets that request to transmit.
OutNUcastPkts: The number of broad-cast and multi-cast packets that
request to transmit.
OutDiscards: The number of outbound packets that are discarded event
the packets is normal.
OutErrors: The The number of outbound packets that could not be
transmitted because of errors.
OutQLen: The length of the output packet queue (in packets).
Sample Type The method of sampling the selected variable and calculating the value to
be compared against the thresholds, possible sample types are:
Absolute: Get the sample directly.
Delta: Calculate the difference between samples (default).
Value
The value of the statistic during the last sampling period.
Startup Alarm The method of sampling the selected variable and calculating the value to
be compared against the thresholds, possible sample types are:
RisingTrigger alarm when the first value is larger than the rising threshold.
FallingTrigger alarm when the first value is less than the falling threshold.
RisingOrFallingTrigger alarm when the first value is larger than the rising
threshold or less than the falling threshold (default).
Rising
Threshold
Rising threshold value (-2147483648-2147483647).
Rising Index Rising event index (1-65535).
Falling
Threshold
Falling threshold value (-2147483648-2147483647)
Falling Index Falling event index (1-65535).
Button
Click to add a new access management entry.
Click to save changes.
Click to undo any changes made locally and revert to previously saved values.
4.3.7.4 Event
Configure RMON Event table on this page. The entry index key is ID.
Items
Description
Delete
Check to delete the entry. It will be deleted during the next save.
ID
Indicates the index of the entry. The range is from 1 to 65535.