Static Unicast
Add static unicast entries to the switch
Network > Static Unicast
In this section, you can add static unicast entries to the switch configuration.
1. Log into your switch management page (see “
Access your switch management page
on page 7).
2. Click on Network and click on Static Unicast.
3. Review the settings.
802.1Q VLAN – Enter the VLAN ID where the MAC address will reside.
Note: By default, all switch ports are part of the default VLAN, VLAN ID 1.
MAC Address – Enter the MAC address of the device to add.
Port Member – Select the port where the MAC address will reside.
Click Apply to add the Static Unicast entry to the list.
In the list, you can click Modify to modify an entry or click Delete or delete the entry.
You can also click Delete All to delete all the entries in the list. If the entries span
multiple pages, you can navigate page number in the Page field and click Go or you can
click First, Previous, Next, and Last Page to navigate the pages.
NOTE: The configured settings are only applied to the switch’s temporary memory and
will be lost upon the next power-cycle. Please follow these next steps to save the
configurations to the switch’s NV-RAM to ensure the settings will remain throughout
power-cycles and reboots:
1.
From the menu on the left: click on Save, then click the blue button Save
Settings to Flash.
2.
Click Continue to return to the Web Configuration of your switch.