background image

IQ3xcite Installation Instructions - Mounting TG200626 Issue 4, 29/12/2010 

1

Installation Instructions – Mounting

IQ3xcite

Web Enabled Controller

Important: Retain these instructions

IQ3xcite Installation Instructions 
- Mounting TG200626

1

Dimensions

2

Requirements

A

0 V

24

 V

24

 V

34  35  36

12

37  38  39

13

40  41  42

14

A

31  32  33

P

11

43  44  45

15

46  47  48

16

100-240 V

OK       RX

P           0

P           0

P           0

P           0 P           0

P           0

4    5    6

2

7    8    9

3

10  11  12

4

13  14  15

5

16  17  18

6

19  20  21

7

22  23  24

8

25  26  27

9

28  29  30

10

+           0

+           0

+           0

+           0

+           0

+           0

+           0

+           0

+           0

1    2    3

1

+           0

a

H

2

O

0 °C
(32 °F)

+45 °C
(113 °F)

0 %RH

90 %RH

b

A

0 V

24

 V

24

 V

34  35  36

12

37  38  39

13

40  41  42

14

A

31  32  33

P

11

43  44  45

15

46  47  48

16

100-240 V

OK       RX

P           0

P           0

P           0

P           0 P           0

P           0

4    5    6

2

7    8    9

3

10  11  12

4

13  14  15

5

16  17  18

6

19  20  21

7

22  23  24

8

25  26  27

9

28  29  30

10

+           0

+           0

+           0

+           0

+           0

+           0

+           0

+           0

+           0

1    2    3

1

+           0

Protection 

IP20, NEMA1

4    5    6

2

7    8    9

3

10  11  12

4

13  14  15

5

16  17  18

6

19  20  21

7

22  23  24

8

25  26  27

9

28  29  30

10

+           0

+           0

+           0

+           0

+           0

+           0

+           0

+           0

+           0

1    2    3

1

+           0

0 V

24 V

24 V

34  35  36

12

37  38  39

13

40  41  42

14

A

31  32  33

P

11

43  44  45

15

46  47  48

16

100-240 V

OK       RX

P           0

P           0

P           0

P           0 P           0

P           0

access for connections

263 mm (10.35”)

access for connections

access for cover, auxiliary board 
option, and I/O bus 

fl

 ap

130 mm (5.12”)

46 mm (1.81”)

150 mm (5.9”)

42 mm (1.65”)

50 mm 

(1.97”)

terminal cover

auxiliary board cover

I/O bus 

fl

 ap 

(I/O bus terminator 

fi

 tted inside)

3 INSTALLATION

1 UNPACKING

2 STORING

It  is  recommended  that  the  installation  should  comply 
with the HSE Memorandum of Guidance on Electricity 
at Work Regulations 1989.
For USA, install equipment in accordance with National 
Electric Code

CONTENTS

1 Unpacking 

.....................................................................1

2 Storing 

...........................................................................1

3 Installation 

.....................................................................1

4 Disposal 

.........................................................................8

H

2

O

+50 °C
(122 °C)

0

-10 °C
(14 °F)

90 %RH

DANGER

: High voltage. No serviceable parts 

inside. Other than removing terminal cover, 

DO NOT OPEN UNIT.

!

WARNING

: If the unit is used in a manner other 

than that speci

fi

 ed in these instructions, the 

protection provided by the unit may be impaired.

continued next page

Summary of Contents for IQ3xcite

Page 1: ...5 16 17 18 6 19 20 21 7 22 23 24 8 25 26 27 9 28 29 30 10 0 0 0 0 0 0 0 0 0 1 2 3 1 0 0 V 24 V 24 V 34 35 36 12 37 38 39 13 40 41 42 14 A 31 32 33 P 11 43 44 45 15 46 47 48 16 100 240 V OK RX P 0 P 0...

Page 2: ...A 31 32 33 P 11 43 44 45 15 46 47 48 16 100 240 V OK RX P 0 P 0 P 0 P 0 P 0 P 0 4 5 6 2 7 8 9 3 10 11 12 4 13 14 15 5 16 17 18 6 19 20 21 7 22 23 24 8 25 26 27 9 28 29 30 10 0 0 0 0 0 0 0 0 0 1 2 3 1...

Page 3: ...structions Configuration TG201160 section 1 step 7 EN61010 2001 MEASUREMENT CATEGORY 1 Separate from 230 Vac input power supply by double or reinforced insulation TP 1 1 22 HF 200 Belden 8761 cable re...

Page 4: ...8 25 26 27 9 28 29 30 10 0 0 0 0 0 0 0 0 0 1 2 3 1 0 0 V 24 V 24 V 34 35 36 12 37 38 39 13 40 41 42 14 A 31 32 33 P 11 43 44 45 15 46 47 48 16 100 240 V OK RX P 0 P 0 P 0 P 0 P 0 P 0 or use 24 Vdc or...

Page 5: ...I O modules can be connected A maximum of 96 or 128 points 16 points in the IQ3xcite and 80 or 112 expansion points can be used The controller and its I O modules are to be fitted inside enclosures No...

Page 6: ...Red White Blue Black 1 2 3 4 5 5 4 3 2 1 or wire special cable using XCITE CC connectors and Belden 3084A cable cable type B left to left Note that the maximum current that can be flow through an I O...

Page 7: ...und White Blue Black Black Red 1 2 3 4 5 5 4 3 2 1 24 Vdc PSU 24 Vdc 0 V Data Hi Data Lo 24 Vdc 0 V Data Hi Data Lo Ground Ground White Blue Black Black Red 1 2 3 4 5 5 4 3 2 1 230 Vac input power sup...

Page 8: ...tems Limited Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereof without obligation to notify any person of such revisi...