background image

 

SS40 SURGE OPERATION / MAINTENANCE MANUAL 

PAGE 3

 

INSTALLATION 

1.1  UNPACKING

 

After unpacking, the surge suppressor should be checked for any damage that 
may have occurred during shipment.  Damage should be reported to the carrier 
immediately. 

The following items should be included within the shipping container: 

Qty 

Item 

Description 

SS40 

SS40 Surge Suppressor 

MSS40 

Operation/Maintenance Manual 

Fitting 

3/8” Male Branch Tee 

2’ 

Tubing 

3/8” PE Tubing 

** 

Seal, Port 

**Dependent upon type of pump option selected. 

1.2  LOCATING / MOUNTING SURGE 

  Remove port plug from pump. 

  Install new port seal. 

  Hand tighten surge suppressor into port.  

Do not

 over tighten. 

ATTENTION: 

Over-tightening adapter into pump will result in pump damage. 

Summary of Contents for SS40

Page 1: ...UMBER located on back of product PATENTS U S 05971402 12 16 2020 MSS40 AB Phone 800 669 1303 or 801 561 0303 Fax 801 255 2312 e mail treborservice idexcorp com SS40 Surge Suppressor Operation Maintenance Manual ...

Page 2: ...TS 1 INSTALLATION 3 1 1 UNPACKING 3 1 2 LOCATING MOUNTING SURGE 3 1 2 a Mounted 4 1 2 b Inline 5 2 MAINTENANCE 6 2 1 RECOMMENDED SPARE PARTS 6 2 2 TOOLS 6 2 3 PARTS ILLUSTRATION 6 2 4 PARTS LIST 7 2 5 CLEAN UP 7 2 6 DISASSEMBLY 7 2 7 ASSEMBLY 8 3 WARRANTY 9 ...

Page 3: ...ems should be included within the shipping container Qty Item Description 1 SS40 SS40 Surge Suppressor 1 MSS40 Operation Maintenance Manual 1 Fitting 3 8 Male Branch Tee 2 Tubing 3 8 PE Tubing 1 Seal Port Dependent upon type of pump option selected 1 2 LOCATING MOUNTING SURGE Remove port plug from pump Install new port seal Hand tighten surge suppressor into port Do not over tighten ATTENTION Over...

Page 4: ...7 31 43 MAXIM 25 12 95 32 89 MAGNUM 620 12 63 32 08 NOTE Install the branch tee in the pump air supply port to replace the pump air connector fitting and then use the supplied tubing to connect between the pump and the SUP port suppressor fitting NOTE When mounted to a Maxim 25E U pump the SS40 requires it s own separate air supply line ...

Page 5: ...SS40 SURGE OPERATION MAINTENANCE MANUAL PAGE 5 1 2 b Inline Figure 1 2 The SS40 Inline must be mounted in an upright position See Figure 1 3 Maxim 25 Figure 1 3 Maxim 25 ...

Page 6: ...ion AT002 1 020 Thick PTFE Diaphragms AT013 1 Pilot Valve Assembly 2 2 TOOLS The following tool kit is recommended as standard service equipment KTSS40 00 A Tool Kit which includes Part No Qty Description 98003108 1 Torque Wrench 30 150 Ft Lb 98003305 1 1 4 Drive Handle T0129 1 Strap Wrench T0146 1 3 4 Pin Tool T0148 1 1 2 Pin Tool 2 3 PARTS ILLUSTRATION ...

Page 7: ...o perform certain preventative maintenance procedures to ensure its continued high performance This Section and Section 2 7 Assembly are provided for the user s convenience in disassembling and re assembling the surge suppressor Thoroughly clean and flush the suppressor and pump before disassembly if possible using DI water Disconnect suppressor air supply line from suppressor Rotate suppressor CC...

Page 8: ...y washed and free from acid residue for handling purposes 2 7 ASSEMBLY Check that all parts are clean and dry Use a new pair of protective gloves to prevent carry over contamination Reverse disassembly procedure starting with reassembling pilot boss assembly Before reinstalling diaphragms check diaphragms for white colored creases or other signs of wear or damage Replace if necessary Complete reas...

Page 9: ... warranty related freight costs shall be borne by the customer Excessive wear to pump components caused by pumping abrasive solutions or chemicals as well as damage caused by ingesting foreign objects shall not be covered by this warranty This warranty shall not apply to any equipment which in the judgment of TREBOR shall have been repaired or altered outside TREBOR s factory in any way so as to a...

Reviews: